Computer Science > Artificial Intelligence
[Submitted on 15 Sep 2017 (v1), last revised 18 Jul 2018 (this version, v4)]
Title:Transforming Cooling Optimization for Green Data Center via Deep Reinforcement Learning
View PDFAbstract:Cooling system plays a critical role in a modern data center (DC). Developing an optimal control policy for DC cooling system is a challenging task. The prevailing approaches often rely on approximating system models that are built upon the knowledge of mechanical cooling, electrical and thermal management, which is difficult to design and may lead to sub-optimal or unstable performances. In this paper, we propose utilizing the large amount of monitoring data in DC to optimize the control policy. To do so, we cast the cooling control policy design into an energy cost minimization problem with temperature constraints, and tap it into the emerging deep reinforcement learning (DRL) framework. Specifically, we propose an end-to-end cooling control algorithm (CCA) that is based on the actor-critic framework and an off-policy offline version of the deep deterministic policy gradient (DDPG) algorithm. In the proposed CCA, an evaluation network is trained to predict an energy cost counter penalized by the cooling status of the DC room, and a policy network is trained to predict optimized control settings when gave the current load and weather information. The proposed algorithm is evaluated on the EnergyPlus simulation platform and on a real data trace collected from the National Super Computing Centre (NSCC) of Singapore. Our results show that the proposed CCA can achieve about 11% cooling cost saving on the simulation platform compared with a manually configured baseline control algorithm. In the trace-based study, we propose a de-underestimation validation mechanism as we cannot directly test the algorithm on a real DC. Even though with DUE the results are conservative, we can still achieve about 15% cooling energy saving on the NSCC data trace if we set the inlet temperature threshold at 26.6 degree Celsius.
Submission history
From: Yuanlong Li [view email][v1] Fri, 15 Sep 2017 07:14:35 UTC (4,218 KB)
[v2] Thu, 24 May 2018 03:13:28 UTC (4,218 KB)
[v3] Mon, 16 Jul 2018 14:32:02 UTC (679 KB)
[v4] Wed, 18 Jul 2018 13:42:59 UTC (679 KB)
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.