8 September 2015 Preliminary study for improving the VIIRS DNB low light calibration accuracy with ground based active light source
Author Affiliations +
Abstract
There is a growing interest in the science and user community in the Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) low light detection capabilities at night for quantitative applications such as airglow, geophysical retrievals under lunar illumination, light power estimation, search and rescue, energy use, urban expansion and other human activities. Given the growing interest in the use of the DNB data, a pressing need arises for improving the calibration stability and absolute accuracy of the DNB at low radiances. Currently the low light calibration accuracy was estimated at a moderate 15%-100% while the long-term stability has yet to be characterized. This study investigates selected existing night light point sources from Suomi NPP DNB observations and evaluates the feasibility of SI traceable nightlight source at radiance levels near 3 nW·cm−2·sr−1, that potentially can be installed at selected sites for VIIRS DNB calibration/validation. The illumination geometry, surrounding environment, as well as atmospheric effects are also discussed. The uncertainties of the ground based light source are estimated. This study will contribute to the understanding of how the Earth’s atmosphere and surface variability contribute to the stability of the DNB measured radiances, and how to separate them from instrument calibration stability. It presents the need for SI traceable active light sources to monitor the calibration stability, radiometric and geolocation accuracy, and point spread functions of the DNB. Finally, it is also hoped to address whether or not active light sources can be used for detecting environmental changes, such as aerosols.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Changyong Cao, Yuqing Zong, Yan Bai, and Xi Shao "Preliminary study for improving the VIIRS DNB low light calibration accuracy with ground based active light source", Proc. SPIE 9607, Earth Observing Systems XX, 96070D (8 September 2015); https://doi.org/10.1117/12.2187580
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Light sources

Bridges

Light

Clouds

Aerosols

Earth's atmosphere

RELATED CONTENT

Design of collimating system for LED source
Proceedings of SPIE (December 31 2013)
Lighting model for natural light in cloudy sky
Proceedings of SPIE (March 22 1996)
Color rendering indices in global illumination methods
Proceedings of SPIE (February 10 2009)

Back to Top