Jump to content

Kilowatt-hour: Difference between revisions

From Wikipedia, the free encyclopedia
Content deleted Content added
No edit summary
Tags: Reverted Mobile edit Mobile web edit
No edit summary
 
(46 intermediate revisions by 26 users not shown)
Line 1: Line 1:
{{Use dmy dates|date=August 2023}}
{{Redirect|KWH}}
{{Short description|Unit of energy, often used for electrical billing}}
{{Short description|Unit of energy, often used for electrical billing}}
{{Redirect|KWH}}
{{Infobox unit
{{Infobox unit
| bgcolor =
| bgcolor =
| name = kilowatt-hour
| name = kilowatt-hour
| image = Hydro quebec meter.JPG
| image = Hydro quebec meter.JPG
| caption = Residential [[electricity meter]] located in j ububybybybCanada
| caption = Residential [[electricity meter]] located in Canada
| standard = Non-SI metric
| standard = Non-SI metric
| quantity = Energy
| quantity = Energy
Line 16: Line 17:
| units2 = [[CGS unit]]s
| units2 = [[CGS unit]]s
| inunits2 = {{convert|1|kW.h|erg|lk=out|disp=out}}
| inunits2 = {{convert|1|kW.h|erg|lk=out|disp=out}}
| units3 = [[English Engineering units]]
| units3 = [[Imperial units]]
| inunits3 = ≈{{thinsp}}{{convert|1|kW.h|ft.lbf|sigfig=7|lk=out|disp=out}}
| inunits3 = ≈{{thinsp}}{{convert|1|kW.h|ftpdl|sigfig=7|lk=out|disp=out}}
| units4 = British Gravitational units
| units4 = [[English Engineering units|English Engineering units (US only)]]
| inunits4 = ≈{{thinsp}}{{convert|1|kW.h|ftpdl|sigfig=7|lk=out|disp=out}}
| inunits4 = ≈{{thinsp}}{{convert|1|kW.h|ft.lbf|sigfig=7|lk=out|disp=out}}
}}
}}
A '''kilowatt-hour''' ([[unit symbol]]: '''kW⋅h''' or '''kW h'''; commonly written as '''kWh''') is a [[Units of measurement|unit]] of [[energy]]: one kilowatt of power for one hour. In terms of [[SI derived units with special names]], it equals 3.6 [[Joule|megajoules]] (MJ). Kilowatt-hours are a common billing unit for electrical energy delivered to consumers by [[Electric utility|electric utilities]].
A '''kilowatt-hour''' ([[unit symbol]]: '''kW⋅h''' or '''kW h'''; commonly written as '''kWh''') is a [[SI unit|non-SI]] [[Units of measurement|unit]] of [[energy]] equal to 3.6 [[Joule|megajoules]] (MJ) in SI units, which is the energy delivered by one [[kilowatt]] of power for one [[hour]]. Kilowatt-hours are a common billing unit for electrical energy supplied by [[Electric utility|electric utilities]]. [[Metric prefix]]es are used for multiples and submultiples of the basic unit, the watt-hour (3.6 kJ).


==Definition==
==Definition==
The kilowatt-hour is a composite unit of energy equal to one kilowatt (kW) sustained for (multiplied by) one hour. Expressed in the standard unit of energy in the [[International System of Units]] (SI), the [[joule]] (symbol J), it is equal to 3,600&nbsp;[[kilojoule]]s or 3.6&nbsp;MJ.<ref>Thompson, Ambler and Taylor, Barry N. (2008). [http://physics.nist.gov/cuu/pdf/sp811.pdf ''Guide for the Use of the International System of Units (SI)''] {{webarchive |url=https://web.archive.org/web/20160603203340/http://physics.nist.gov/cuu/pdf/sp811.pdf |date=June 3, 2016 }} (Special publication 811). Gaithersburg, MD: National Institute of Standards and Technology. 12.</ref><ref name="taylor2001">"Half-high dots or spaces are used to express a derived unit formed from two or more other units by multiplication.", Barry N. Taylor. (2001 ed.) [http://physics.nist.gov/Pubs/SP330/sp330.pdf ''The International System of Units.''] {{webarchive|url=https://web.archive.org/web/20160603215953/http://physics.nist.gov/Pubs/SP330/sp330.pdf |date=June 3, 2016 }} (Special publication 330). Gaithersburg, MD: National Institute of Standards and Technology. 20.</ref>
The kilowatt-hour is a composite unit of energy equal to one kilowatt (kW) sustained for (multiplied by) one hour. The [[International System of Units]] (SI) unit of energy meanwhile is the [[joule]] (symbol J). Because a [[watt]] is by definition one [[joule]] per [[second]], and because there are 3,600 [[seconds]] in an hour, one kWh equals 3,600&nbsp;[[kilojoule]]s or 3.6&nbsp;MJ.<ref>Thompson, Ambler and Taylor, Barry N. (2008). [http://physics.nist.gov/cuu/pdf/sp811.pdf ''Guide for the Use of the International System of Units (SI)''] {{webarchive |url=https://web.archive.org/web/20160603203340/http://physics.nist.gov/cuu/pdf/sp811.pdf |date=3 June 2016 }} (Special publication 811). Gaithersburg, MD: National Institute of Standards and Technology. 12.</ref><ref name="taylor2001">"Half-high dots or spaces are used to express a derived unit formed from two or more other units by multiplication.", Barry N. Taylor. (2001 ed.) [http://physics.nist.gov/Pubs/SP330/sp330.pdf ''The International System of Units.''] {{webarchive|url=https://web.archive.org/web/20160603215953/http://physics.nist.gov/Pubs/SP330/sp330.pdf |date=3 June 2016 }} (Special publication 330). Gaithersburg, MD: National Institute of Standards and Technology. 20.</ref>


==Unit representations==
==Unit representations==
A widely used representation of the kilowatt-hour is "kWh", derived from its component units, kilowatt and hour. It is commonly used in billing for delivered energy to consumers by [[electric utility]] companies, and in commercial, educational, and scientific publications, and in the media.<ref>[http://www.electropedia.org/iev/iev.nsf/display?openform&ievref=131-11-58 IEC Electropedia, Entry 131-11-58] {{webarchive |url=https://web.archive.org/web/20160314215740/http://www.electropedia.org/iev/iev.nsf/display?openform&ievref=131-11-58 |date=March 14, 2016 }}</ref><ref>See for example: [http://www.windpower.org/en/stat/unitsene.htm ''Wind Energy Reference Manual Part 2: Energy and Power Definitions''] {{webarchive |url= https://web.archive.org/web/20071126132157/http://www.windpower.org/en/stat/unitsene.htm |date=November 26, 2007 }} Danish Wind Energy Association. Retrieved 9 January 2008; [http://www.businessdictionary.com/definition/Kilowatt-Hour-kWh.html "Kilowatt-Hour (kWh)"] {{webarchive|url=https://web.archive.org/web/20160302222956/http://www.businessdictionary.com/definition/Kilowatt-Hour-kWh.html |date=March 2, 2016 }} BusinessDictionary.com. Retrieved 9 January 2008; [http://www.world-nuclear.org/info/inf41.html "US Nuclear Power Industry"] {{webarchive|url=https://web.archive.org/web/20071126132157/http://www.world-nuclear.org/info/inf41.html |date=November 26, 2007 }} www.world-nuclear.org. Retrieved 9 January 2008; [http://eeru.open.ac.uk/natta/energy.html#4 "Energy. A Beginners Guide: Making Sense of Units"] {{webarchive | url= https://web.archive.org/web/20071126132157/http://eeru.open.ac.uk/natta/energy.html |date=November 26, 2007 }} ''Renew On Line (UK)''. The [[Open University]]. Retrieved 9 January 2008.</ref> It is also the usual unit representation in electrical power engineering.<ref>ASTM SI10-10, IEEE/ASTM SI 10 American National Standard for Metric Practice, ASTM International, West Conshohocken, PA, 2010, [www.astm.org] "The symbols for certain compound units of electrical power engineering are usually written without separation, thus: watthour (Wh), kilowatthour (kWh), voltampere (VA), and kilovoltampere (kVA)"</ref> This common representation, however, does not comply with the [[style guide]] of the [[International System of Units]] (SI).<ref name="BIPM">{{cite web |title=The International System of Units (SI) |url=https://www.bipm.org/utils/common/pdf/si-brochure/SI-Brochure-9-EN.pdf#page=33 |publisher=International Bureau of Weights and Measures (BIPM) |access-date=7 April 2020 |page=147 |date=2019}}</ref>
A widely used representation of the kilowatt-hour is ''kWh'', derived from its component units, kilowatt and hour. It is commonly used in billing for delivered energy to consumers by [[electric utility]] companies, and in commercial, educational, and scientific publications, and in the media.<ref>[http://www.electropedia.org/iev/iev.nsf/display?openform&ievref=131-11-58 IEC Electropedia, Entry 131-11-58] {{webarchive |url=https://web.archive.org/web/20160314215740/http://www.electropedia.org/iev/iev.nsf/display?openform&ievref=131-11-58 |date=14 March 2016 }}</ref><ref>See for example: [http://www.windpower.org/en/stat/unitsene.htm ''Wind Energy Reference Manual Part 2: Energy and Power Definitions''] {{webarchive |url= https://web.archive.org/web/20071126132157/http://www.windpower.org/en/stat/unitsene.htm |date=26 November 2007 }} Danish Wind Energy Association. Retrieved 9 January 2008; [http://www.businessdictionary.com/definition/Kilowatt-Hour-kWh.html "Kilowatt-Hour (kWh)"] {{webarchive|url=https://web.archive.org/web/20160302222956/http://www.businessdictionary.com/definition/Kilowatt-Hour-kWh.html |date=2 March 2016 }} BusinessDictionary.com. Retrieved 9 January 2008; [http://www.world-nuclear.org/info/inf41.html "US Nuclear Power Industry"] {{webarchive|url=https://web.archive.org/web/20071126132157/http://www.world-nuclear.org/info/inf41.html |date=26 November 2007 }} www.world-nuclear.org. Retrieved 9 January 2008; [http://eeru.open.ac.uk/natta/energy.html#4 "Energy. A Beginners Guide: Making Sense of Units"] {{webarchive | url= https://web.archive.org/web/20071126132157/http://eeru.open.ac.uk/natta/energy.html |date=26 November 2007 }} ''Renew On Line (UK)''. The [[Open University]]. Retrieved 9 January 2008.</ref> It is also the usual unit representation in electrical power engineering.<ref>ASTM SI10-10, IEEE/ASTM SI 10 American National Standard for Metric Practice, ASTM International, West Conshohocken, PA, 2010, [www.astm.org] "The symbols for certain compound units of electrical power engineering are usually written without separation, thus: watthour (Wh), kilowatthour (kWh), voltampere (VA), and kilovoltampere (kVA)"</ref> This common representation, however, does not comply with the [[style guide]] of the [[International System of Units]] (SI).<ref name="BIPM">{{cite web |title=The International System of Units (SI) |url=https://www.bipm.org/utils/common/pdf/si-brochure/SI-Brochure-9-EN.pdf#page=33 |publisher=International Bureau of Weights and Measures (BIPM) |access-date=7 April 2020 |page=147 |date=2019}}</ref>


Other representations of the unit may be encountered:
Other representations of the unit may be encountered:
* "kW⋅h" and "kW&nbsp;h" are less commonly used, but they are consistent with the SI. The SI brochure<ref name="BIPM" /> states that in forming a compound unit symbol, "Multiplication must be indicated by a space or a [[interpunct|half-high (centred) dot]] (⋅), since otherwise some prefixes could be misinterpreted as a unit symbol." This is supported by a voluntary standard<ref>Standard for the Use of the International System of Units (SI): The Modern Metric System. (1997). (IEEE/ASTM SI 10-1997). New York and West Conshohocken, PA: [[Institute of Electrical and Electronics Engineers]] and [[ASTM]]. 15.</ref> issued jointly by an international ([[Institute of Electrical and Electronics Engineers|IEEE]]) and national ([[ASTM International|ASTM]]) organization, and by a major style guide.<ref>{{cite book |title=The Chicago Manual of Style |date=2017 |publisher=University of Chicago Press |location=Chicago |edition=17 |url=https://www.chicagomanualofstyle.org/book/ed17/part2/ch10/psec058.html |access-date=1 April 2020 |chapter=10.57: Units derived from SI base units}}</ref> However, the IEEE/ASTM standard allows "kWh" (but does not mention other multiples of the watt-hour). One guide published by [[National Institute of Standards and Technology|NIST]] specifically recommends against "kWh" "to avoid possible confusion".<ref>{{cite web | url= https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication811e2008.pdf | title= Guide for the Use of the International System of Units (SI) | publisher = [[National Institute of Standards and Technology]] | year= 2008 | quote = Reference [4: ISO 31-0] suggests that if a space is used to indicate units formed by multiplication, the space may be omitted if it does not cause confusion. This possibility is reflected in the common practice of using the symbol kWh rather than kW⋅h or kW&nbsp;h for the kilowatt-hour. Nevertheless, this Guide takes the position that a half-high dot or a space should always be used to avoid possible confusion; | access-date= 6 April 2020}}</ref>
* ''kW⋅h'' and ''kW&nbsp;h'' are less commonly used, but they are consistent with the SI. The SI brochure<ref name="BIPM" /> states that in forming a compound unit symbol, "Multiplication must be indicated by a space or a [[interpunct|half-high (centred) dot]] (⋅), since otherwise some prefixes could be misinterpreted as a unit symbol." This is supported by a standard<ref>Standard for the Use of the International System of Units (SI): The Modern Metric System. (1997). (IEEE/ASTM SI 10-1997). New York and West Conshohocken, PA: [[Institute of Electrical and Electronics Engineers]] and [[ASTM]]. 15.</ref> issued jointly by an international ([[Institute of Electrical and Electronics Engineers|IEEE]]) and national ([[ASTM International|ASTM]]) organization, and by a major style guide.<ref>{{cite book |title=The Chicago Manual of Style |date=2017 |publisher=University of Chicago Press |location=Chicago |edition=17 |url=https://www.chicagomanualofstyle.org/book/ed17/part2/ch10/psec058.html |access-date=1 April 2020 |chapter=10.57: Units derived from SI base units}}</ref> However, the IEEE/ASTM standard allows ''kWh'' (but does not mention other multiples of the watt-hour). One guide published by [[National Institute of Standards and Technology|NIST]] specifically recommends against ''kWh'' "to avoid possible confusion".<ref>{{cite web | url= https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication811e2008.pdf | title= Guide for the Use of the International System of Units (SI) | publisher = [[National Institute of Standards and Technology]] | year= 2008 | quote = Reference [4: ISO 31-0] suggests that if a space is used to indicate units formed by multiplication, the space may be omitted if it does not cause confusion. This possibility is reflected in the common practice of using the symbol kWh rather than kW⋅h or kW&nbsp;h for the kilowatt-hour. Nevertheless, this Guide takes the position that a half-high dot or a space should always be used to avoid possible confusion; | access-date= 6 April 2020}}</ref>
* The United States official fuel-economy [[window sticker]] for electric vehicles uses the abbreviation "kW-hrs".<ref name=fueleconomy>{{cite web|title=Electric Vehicles: Learn More About the New Label |url= http://www.fueleconomy.gov/feg/label/learn-more-electric-label.shtml |website=fueleconomy.gov|publisher=US Department of energy|access-date=10 August 2014}}</ref>
* In 2014, the United States official fuel-economy [[window sticker]] for electric vehicles used the abbreviation ''kW-hrs''.<ref name=fueleconomy>{{cite web|title=Electric Vehicles: Learn More About the New Label |url= http://www.fueleconomy.gov/feg/label/learn-more-electric-label.shtml |website=fueleconomy.gov|publisher=US Department of energy|access-date=10 August 2014}}</ref>
* Variations in capitalization are sometimes encountered: KWh, KWH, kwh, etc., which are inconsistent with the International System of Units.
* Variations in capitalization are sometimes encountered: ''KWh'', ''KWH'', ''kwh'', etc., which are inconsistent with the International System of Units.
* The notation "kW/h" for the kilowatt-hour is incorrect, as it denotes kilowatt per hour.
* The notation ''kW/h'' for the kilowatt-hour is incorrect, as it denotes kilowatt per hour.


The hour is a unit of time listed among the [[Non-SI units mentioned in the SI|non-SI units accepted]] by the [[International Bureau of Weights and Measures]] for use with the SI.<ref name=BIPM /> Its combination with the kilowatt, a standard SI unit, is therefore permitted within the standard.{{dubious|date=October 2022}}
The hour is a unit of time listed among the [[Non-SI units mentioned in the SI|non-SI units accepted]] by the [[International Bureau of Weights and Measures]] for use with the SI.<ref name=BIPM />


An electric heater consuming 1,000 watts (1 kilowatt), and operating for one hour uses one kilowatt-hour of energy. A television consuming 100 watts operating continuously for 10 hours uses one kilowatt-hour. A 40-watt electric appliance operating continuously for 25 hours uses one kilowatt-hour.
An electric heater consuming 1,000 watts (1 kilowatt) operating for one hour uses one kilowatt-hour of energy. A television consuming 100 watts operating continuously for 10 hours uses one kilowatt-hour. A 40-watt electric appliance operating continuously for 25 hours uses one kilowatt-hour.


==Electricity sales==
==Electricity sales==
Electrical energy is typically sold to consumers in kilowatt-hours. The cost of running an electrical device is calculated by multiplying the device's power consumption in kilowatts by the operating time in hours, and by the price per kilowatt-hour. The [[unit price]] of electricity charged by utility companies may depend on the customer's consumption profile over time. Prices vary considerably by locality. In the United States prices in different states can vary by a factor of three.<ref>[https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a Average Price of Electricity to Ultimate Customers by End-Use Sector], U.S. Energy Information Administration, April 2018</ref>
Electrical energy is typically sold to consumers in kilowatt-hours. The cost of running an electrical device is calculated by multiplying the device's power consumption in kilowatts by the operating time in hours, and by the price per kilowatt-hour. The [[unit price]] of electricity charged by utility companies may depend on the customer's consumption profile over time. Prices vary considerably by locality. In the United States prices in different states can vary by a factor of three.<ref>[https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a Average Price of Electricity to Ultimate Customers by End-Use Sector], U.S. Energy Information Administration, April 2018</ref>


While smaller customer loads are usually billed only for energy, transmission services, and the rated capacity, larger consumers also pay for peak power consumption, the greatest power recorded in a fairly short time, such as 15 minutes. This compensates the power company for maintaining the infrastructure needed to provide peak power. These charges are billed as demand changes.<ref>[https://www.nationalgridus.com/niagaramohawk/non_html/eff_elec-demand.pdf "Understanding Electric Demand"] {{webarchive |url=https://web.archive.org/web/20160606043318/https://www.nationalgridus.com/niagaramohawk/non_html/eff_elec-demand.pdf |date=June 6, 2016 }}, National Grid</ref> Industrial users may also have extra charges according to the [[power factor]] of their load.
While smaller customer loads are usually billed only for energy, transmission services, and the rated capacity, larger consumers also pay for peak power consumption, the greatest power recorded in a fairly short time, such as 15 minutes. This compensates the power company for maintaining the infrastructure needed to provide peak power. These charges are billed as demand changes.<ref>[https://www.nationalgridus.com/niagaramohawk/non_html/eff_elec-demand.pdf "Understanding Electric Demand"] {{webarchive |url=https://web.archive.org/web/20160606043318/https://www.nationalgridus.com/niagaramohawk/non_html/eff_elec-demand.pdf |date=6 June 2016 }}, National Grid</ref> Industrial users may also have extra charges according to the [[power factor]] of their load.


Major energy production or consumption is often expressed as terawatt-hours (TWh) for a given period that is often a [[calendar year]] or [[fiscal year|financial year]]. A 365-day year equals 8,760 hours, so over a period of one year, power of one gigawatt equates to 8.76 terawatt-hours of energy. Conversely, one terawatt-hour is equal to a sustained power of about 114 megawatts for a period of one year.
Major energy production or consumption is often expressed as terawatt-hours (TWh) for a given period that is often a [[calendar year]] or [[fiscal year|financial year]]. A 365-day year equals 8,760 hours, so over a period of one year, power of one gigawatt equates to 8.76 terawatt-hours of energy. Conversely, one terawatt-hour is equal to a sustained power of about 114 megawatts for a period of one year.


==Examples==
==Examples==
In 2020, the average household in the United States consumed 893 kWh per month.<ref>{{cite web|title=How much electricity does an American home use?|url=https://www.eia.gov/tools/faqs/faq.php?id=97&t=3#:~:text=How%20much%20electricity%20does%20an,about%20893%20kWh%20per%20month.|publisher=U.S. Energy Information Administration|access-date=2022-06-11|date=2021-10-07}}</ref>
In 2020, the average household in the United States consumed 893 kWh per month.<ref>{{cite web|title=How much electricity does an American home use?|url=https://www.eia.gov/tools/faqs/faq.php?id=97&t=3#:~:text=How%20much%20electricity%20does%20an,about%20893%20kWh%20per%20month.|publisher=U.S. Energy Information Administration|access-date=11 June 2022|date=7 October 2021}}</ref>

Raising the temperature of 1 [[litre]] of water from [[room temperature]] to the boiling point with an [[electric kettle]] takes about 0.1 kWh.

A 12 watt [[LED lamp]] lit constantly uses about 0.3 kW⋅h per 24 hours and about 9 kWh per month.


In terms of [[human power]], a healthy adult male manual laborer performs work equal to about half a kilowatt-hour over an eight-hour day.<ref>Eugene A. Avallone et al., (ed), ''Marks' Standard Handbook for Mechanical Engineers 11th Edition '', Mc-Graw Hill, New York 2007 {{ISBN|0-07-142867-4}} page 9-4</ref>
In terms of [[human power]], a healthy adult male manual laborer performs work equal to about half a kilowatt-hour over an eight-hour day.<ref>Eugene A. Avallone et al., (ed), ''Marks' Standard Handbook for Mechanical Engineers 11th Edition '', Mc-Graw Hill, New York 2007 {{ISBN|0-07-142867-4}} page 9-4</ref>
Line 64: Line 69:
! [[Calorie]]
! [[Calorie]]
|-
|-
! {{rh|align=right}} | 1 J = 1 kg⋅m<sup>2</sup>⋅s<sup>−2</sup> =
! {{rh|align=right}} | 1 J = 1&nbsp;kg⋅m<sup>2</sup>⋅s<sup>−2</sup> =
| 1
| 1
| 2.77778 × 10<sup>−4</sup>
| 2.77778 × 10<sup>−4</sup>
Line 101: Line 106:


==Watt-hour multiples {{anchor|Multiples}}==<!-- This section is linked from [[Economy of France]] and many other articles -->
==Watt-hour multiples {{anchor|Multiples}}==<!-- This section is linked from [[Economy of France]] and many other articles -->
{{SI multiples 2
|symbol=W⋅h
|unit=watt-hour
|anchor=Multiples
|mlo=3
|smlo=3
|mhi=15
|smhi=6
|right=
}}
{{Further|Metric prefix}}
{{Further|Metric prefix}}
{| class="wikitable floatright" style="text-align: center;"
|+ SI multiples of watt-hour (W⋅h)
|-
! scope="col" | Value
! scope="col" | Symbol
! scope="col" | Name
|-
| {{10^|-6}} || μW⋅h || microwatt-hour
|-
| {{10^|-3}} || mW⋅h || milliwatt-hour
|-
| {{10^|0}} || W⋅h || watt-hour
|-
| {{10^|3}} || kW⋅h || kilowatt-hour
|-
| {{10^|6}} || MW⋅h || megawatt-hour
|-
| {{10^|9}} || GW⋅h || gigawatt-hour
|-
| {{10^|12}} || TW⋅h || terawatt-hour
|-
| {{10^|15}} || PW⋅h || petawatt-hour
|}


All the [[Metric prefix|SI prefixes]] are commonly applied to the watt-hour: a kilowatt-hour is 1,000 Wh (kWh); a megawatt-hour is 1 million Wh (MWh); a milliwatt-hour is 1/1,000 Wh (mWh) and so on.
All the [[Metric prefix|SI prefixes]] are commonly applied to the watt-hour: a kilowatt-hour is 1,000 Wh (kWh); a megawatt-hour is 1 million Wh (MWh); a milliwatt-hour is 1/1,000 Wh (mWh) and so on.
The kilowatt-hour is commonly used by electrical energy providers for purposes of billing, since the monthly energy consumption of a typical residential customer ranges from a few hundred to a few thousand kilowatt-hours. '''Megawatt-hours''' (MWh), '''gigawatt-hours''' (GWh), and '''terawatt-hours''' (TWh) are often used for metering larger amounts of electrical energy to industrial customers and in power generation. The terawatt-hour and '''petawatt-hour''' (PWh) units are large enough to conveniently express the [[list of countries by electricity production|annual electricity generation for whole countries]] and the [[world energy supply and consumption|world energy consumption]].
The kilowatt-hour is commonly used by electrical energy providers for purposes of billing, since the monthly energy consumption of a typical residential customer ranges from a few hundred to a few thousand kilowatt-hours. '''Megawatt-hours''' (MWh), '''gigawatt-hours''' (GWh), and '''terawatt-hours''' (TWh) are often used for metering larger amounts of electrical energy to industrial customers and in power generation. The terawatt-hour and '''petawatt-hour''' (PWh) units are large enough to conveniently express the [[list of countries by electricity production|annual electricity generation for whole countries]] and the [[world energy supply and consumption|world energy consumption]].


==Distinguishing between kilowatt-hours (energy) and kilowatts (power)==<!-- if you rename this section please update the redirect at [[Kilowatts per hour]] -->
==Distinction between kWh (energy) and kW (power)==
A kilowatt is a unit of power (rate of flow of energy per unit of time). A kilowatt-hour is a unit of energy. Kilowatt per hour would be a rate of change of power flow with time.

[[work (physics)|Work]] is the amount of energy transferred to a system; [[Power (physics)|power]] is the ''rate of delivery'' of energy.
[[work (physics)|Work]] is the amount of energy transferred to a system; [[Power (physics)|power]] is the ''rate of delivery'' of energy.
Energy is measured in ''joules'', or ''watt-seconds''. Power is measured in ''watts'', or ''joules per second''.
Energy is measured in ''joules'', or ''watt-seconds''. Power is measured in ''watts'', or ''joules per second''.
Line 123: Line 143:


===Annualized power===
===Annualized power===
Electric energy production and consumption are sometimes reported on a yearly basis, in units such as megawatt-hours per year (MWh/yr) gigawatt-hours/year (GWh/yr) or terawatt-hours per year (TWh/yr). These units have dimensions of energy divided by time and thus are units of power. They can be converted to SI power units by dividing by the number of hours in a year, about {{val|8766|u=h|up=yr}}.
Electric energy production and consumption are sometimes reported on a yearly basis, in units such as megawatt-hours per year (MWh/yr) gigawatt-hours/year (GWh/yr) or terawatt-hours per year (TWh/yr). These units have dimensions of energy divided by time and thus are units of power. They can be converted to SI power units by dividing by the number of hours in a year, about {{val|8760|u=h|up=yr}}.


Thus, 1&nbsp;GWh/yr = 1&nbsp;GWh/8766&nbsp;h ≈ {{val|114.08|u=kW}}.
Thus, 1&nbsp;GWh/yr = 1&nbsp;GWh/8760&nbsp;h ≈ {{val|114.12|u=kW}}.


===Misuse of watts per hour{{anchor|Watt per hour}}===
===Misuse of watts per hour{{anchor|Watt per hour}}===
Many compound units for various kinds of rates explicitly mention units of time to indicate a change over time. For example: miles per hour, kilometres per hour, dollars per hour. Power units, such as kW, already measure the rate of energy per unit time (kW=[[kilojoule|kJ]]/[[second|s]]). Kilowatt-hours are a product of power and time, not a rate of change of power with time.
Many compound units for various kinds of rates explicitly mention units of time to indicate a change over time. For example: miles per hour, kilometres per hour, dollars per hour. Power units, such as kW, already measure the rate of energy per unit time (kW=[[kilojoule|kJ]]/[[second|s]]). Kilowatt-hours are a product of power and time, not a rate of change of power with time.


Watts per hour (W/h) is a unit of a ''change'' of power per hour, i.e. an acceleration in the delivery of energy. It is used to measure the daily variation of demand (e.g. the slope of the [[duck curve]]), or ramp-up behavior of [[power plant]]s. For example, a power plant that reaches a power output of {{val|1|u=MW}} from {{val|0|u=MW}} in 15 minutes has a ramp-up rate of {{val|4|u=MW|up=h}}.
Watts per hour (W/h) is a unit of a ''change'' of power per hour, i.e. an acceleration in the delivery of energy. It is used to measure the daily variation of demand (e.g. the slope of the [[duck curve]]), or ramp-up behavior of [[power plant]]s. For example, a power plant that reaches a power output of {{val|1|u=MW}} from {{val|0|u=MW}} in 15 minutes has a ramp-up rate of {{val|4|u=MW|up=h}}.


Other uses of terms such as ''watts per hour'' are likely to be errors.<ref>{{Cite book |last=Woofenden |first=Ian |url=https://books.google.com/books?id=iYktDwAAQBAJ&dq=%22watts+per+hour%22+%22nonsensical+phrase%22&pg=PA48 |title=Wind Power For Dummies |date=2009-10-05 |publisher=John Wiley & Sons |isbn=978-0-470-49637-4 |pages=48 |language=en |quote=Much too often, I hear people say something like ... 'watts per hour'...}}</ref><ref>{{Cite book |url=https://books.google.com/books?id=NvRIAQAAIAAJ&q=%22watts+per+hour%22+(mistake+OR+error+OR+blunder) |title=Home Power |date=2007 |publisher=Electron Connection |language=en |quote="Watts per hour. This nonsensical phrase tops my electrical terminology pet peeve list."}}</ref>
Other uses of terms such as ''watts per hour'' are likely to be errors.<ref>{{Cite book |last=Woofenden |first=Ian |url=https://books.google.com/books?id=iYktDwAAQBAJ&dq=%22watts+per+hour%22+%22nonsensical+phrase%22&pg=PA48 |title=Wind Power For Dummies |date=5 October 2009 |publisher=John Wiley & Sons |isbn=978-0-470-49637-4 |pages=48 |language=en |quote=Much too often, I hear people say something like ... 'watts per hour'...}}</ref><ref>{{Cite book |url=https://books.google.com/books?id=NvRIAQAAIAAJ&q=%22watts+per+hour%22+(mistake+OR+error+OR+blunder) |title=Home Power |date=2007 |publisher=Electron Connection |language=en |quote="Watts per hour. This nonsensical phrase tops my electrical terminology pet peeve list."}}</ref>


==Other related energy units==
==Other related energy units==
Line 138: Line 158:
Several other units related to kilowatt-hour are commonly used to indicate power or energy capacity or use in specific application areas.
Several other units related to kilowatt-hour are commonly used to indicate power or energy capacity or use in specific application areas.
Average annual energy production or consumption can be expressed in kilowatt-hours per year. This is used with loads or output that vary during the year but whose annual totals are similar from one year to the next. For example, it is useful to compare the energy efficiency of household appliances whose power consumption varies with time or the season of the year. Another use is to measure the energy produced by a distributed power source. One kilowatt-hour per year equals about 114.08 [[milliwatt]]s applied constantly during one year.
Average annual energy production or consumption can be expressed in kilowatt-hours per year. This is used with loads or output that vary during the year but whose annual totals are similar from one year to the next. For example, it is useful to compare the [[Efficient energy use|energy efficiency]] of household appliances whose power consumption varies with time or the season of the year. Another use is to measure the energy produced by a distributed power source. One kilowatt-hour per year equals about 114.08 [[milliwatt]]s applied constantly during one year.


The energy content of a [[battery (electricity)|battery]] is usually expressed indirectly by its capacity in [[ampere-hour]]s; to convert ampere-hour (Ah) to watt-hours (Wh), the ampere-hour value must be multiplied by the voltage of the power source. This value is approximate, since the battery voltage is not constant during its discharge, and because higher discharge rates reduce the total amount of energy that the battery can provide. In the case of devices that output a different voltage than the battery, it is the battery voltage (typically 3.7&nbsp;V for [[Li-ion]]) that must be used to calculate rather than the device output (for example, usually 5.0&nbsp;V for [[USB]] portable chargers). This results in a 500&nbsp;mA USB device running for about 3.7 hours on a 2,500&nbsp;mAh battery, not five hours.
The energy content of a [[battery (electricity)|battery]] is usually expressed indirectly by its capacity in [[ampere-hour]]s; to convert ampere-hour (Ah) to watt-hours (Wh), the ampere-hour value must be multiplied by the voltage of the power source. This value is approximate, since the battery voltage is not constant during its discharge, and because higher discharge rates reduce the total amount of energy that the battery can provide. In the case of devices that output a different voltage than the battery, it is the battery voltage (typically 3.7&nbsp;V for [[Li-ion]]) that must be used to calculate rather than the device output (for example, usually 5.0&nbsp;V for [[USB]] portable chargers). This results in a 500&nbsp;mA USB device running for about 3.7 hours on a 2,500&nbsp;mAh battery, not five hours.


The ''Board of Trade unit'' (B.T.U.)<ref>{{cite book|editor=E. M. Kirkpatrick|title=[[Chambers 20th Century Dictionary]]|edition=New|year=1983|publisher=Chambers|location=Edinburgh|isbn=0550102345|page=137}}</ref> is an obsolete UK synonym for kilowatt-hour. The term derives from the name of the [[Board of Trade]] which regulated the electricity industry until 1942 when the [[Ministry of Power (United Kingdom)|Ministry of Power]] took over.<ref>{{cite web|title=The Board of Trade 1621-1970|url=http://www.berr.gov.uk/aboutus/corporate/history/outlines/BT-1621-1970/page13919.html|archive-url=http://webarchive.nationalarchives.gov.uk/20100304150704/http://www.berr.gov.uk/aboutus/corporate/history/outlines/BT-1621-1970/page13919.html|archive-date=2010}}</ref> This should not be confused with a [[British Thermal Unit]] (BTU) which is 1055 J.
The ''Board of Trade unit'' (B.T.U.)<ref>{{cite book|editor=E. M. Kirkpatrick|title=[[Chambers 20th Century Dictionary]]|edition=New|year=1983|publisher=Chambers|location=Edinburgh|isbn=0550102345|page=137}}</ref> is an obsolete UK synonym for kilowatt-hour. The term derives from the name of the [[Board of Trade]] which regulated the electricity industry until 1942 when the [[Ministry of Power (United Kingdom)|Ministry of Power]] took over.<ref>{{cite web|title=The Board of Trade 1621-1970|url=http://www.berr.gov.uk/aboutus/corporate/history/outlines/BT-1621-1970/page13919.html |website=Department for Business Innovation and Skills |archive-url=http://webarchive.nationalarchives.gov.uk/20100304150704/http://www.berr.gov.uk/aboutus/corporate/history/outlines/BT-1621-1970/page13919.html|archive-date=4 March 2010}}</ref> This should not be confused with a [[British Thermal Unit]] (BTU) which is 1055 J.


In India, the kilowatt-hour is often simply called a ''Unit'' of energy. A million units, designated ''MU'', is a gigawatt-hour and a BU (billion units) is a terawatt-hour.<ref>{{cite news|url=http://www.financialexpress.com/printer/news/122151/ |archive-url=https://archive.today/20120908010852/http://www.financialexpress.com/printer/news/122151/ |url-status=dead |archive-date=September 8, 2012 |title=Get enlightened about electricity |date=December 20, 2004 |work=[[The Financial Express (India)|The Financial Express]] |access-date=29 November 2009 }}</ref><ref>{{cite news | url=http://www.hindu.com/holnus/006200807241521.htm | archive-url= https://web.archive.org/web/20121107155200/http://www.hindu.com/holnus/006200807241521.htm | url-status=dead | archive-date=November 7, 2012 | title=BHEL manufactured units generate record power | date=July 24, 2008 | work=[[The Hindu]] | agency=[[Press Trust of India]] |access-date=29 November 2009}}</ref>
In India, the kilowatt-hour is often simply called a ''unit'' of energy. A million units, designated ''MU'', is a gigawatt-hour and a ''BU'' (billion units) is a terawatt-hour.<ref>{{cite news|url=http://www.financialexpress.com/printer/news/122151/ |archive-url=https://archive.today/20120908010852/http://www.financialexpress.com/printer/news/122151/ |url-status=dead |archive-date=8 September 2012 |title=Get enlightened about electricity |date=20 December 2004 |work=[[The Financial Express (India)|The Financial Express]] |access-date=29 November 2009 }}</ref><ref>{{cite news | url=http://www.hindu.com/holnus/006200807241521.htm | archive-url= https://web.archive.org/web/20121107155200/http://www.hindu.com/holnus/006200807241521.htm | url-status=dead | archive-date=7 November 2012 | title=BHEL manufactured units generate record power | date=24 July 2008 | work=[[The Hindu]] | agency=[[Press Trust of India]] |access-date=29 November 2009}}</ref>


==See also==
==See also==
Line 155: Line 175:
==References==
==References==
{{Reflist}}
{{Reflist}}



{{DEFAULTSORT:Kilowatt Hour}}
{{DEFAULTSORT:Kilowatt Hour}}

Latest revision as of 16:37, 18 October 2024

kilowatt-hour
Residential electricity meter located in Canada
General information
Unit systemNon-SI metric
Unit ofEnergy
SymbolkW⋅h, kW h
Conversions
1 kW⋅h in ...... is equal to ...
   SI units   3.6 MJ
   CGS units   3.6×1013 erg
   Imperial units   85,429,300 ft⋅pdl
   English Engineering units (US only)   2,655,224 ft⋅lbf

A kilowatt-hour (unit symbol: kW⋅h or kW h; commonly written as kWh) is a non-SI unit of energy equal to 3.6 megajoules (MJ) in SI units, which is the energy delivered by one kilowatt of power for one hour. Kilowatt-hours are a common billing unit for electrical energy supplied by electric utilities. Metric prefixes are used for multiples and submultiples of the basic unit, the watt-hour (3.6 kJ).

Definition

[edit]

The kilowatt-hour is a composite unit of energy equal to one kilowatt (kW) sustained for (multiplied by) one hour. The International System of Units (SI) unit of energy meanwhile is the joule (symbol J). Because a watt is by definition one joule per second, and because there are 3,600 seconds in an hour, one kWh equals 3,600 kilojoules or 3.6 MJ.[1][2]

Unit representations

[edit]

A widely used representation of the kilowatt-hour is kWh, derived from its component units, kilowatt and hour. It is commonly used in billing for delivered energy to consumers by electric utility companies, and in commercial, educational, and scientific publications, and in the media.[3][4] It is also the usual unit representation in electrical power engineering.[5] This common representation, however, does not comply with the style guide of the International System of Units (SI).[6]

Other representations of the unit may be encountered:

  • kW⋅h and kW h are less commonly used, but they are consistent with the SI. The SI brochure[6] states that in forming a compound unit symbol, "Multiplication must be indicated by a space or a half-high (centred) dot (⋅), since otherwise some prefixes could be misinterpreted as a unit symbol." This is supported by a standard[7] issued jointly by an international (IEEE) and national (ASTM) organization, and by a major style guide.[8] However, the IEEE/ASTM standard allows kWh (but does not mention other multiples of the watt-hour). One guide published by NIST specifically recommends against kWh "to avoid possible confusion".[9]
  • In 2014, the United States official fuel-economy window sticker for electric vehicles used the abbreviation kW-hrs.[10]
  • Variations in capitalization are sometimes encountered: KWh, KWH, kwh, etc., which are inconsistent with the International System of Units.
  • The notation kW/h for the kilowatt-hour is incorrect, as it denotes kilowatt per hour.

The hour is a unit of time listed among the non-SI units accepted by the International Bureau of Weights and Measures for use with the SI.[6]

An electric heater consuming 1,000 watts (1 kilowatt) operating for one hour uses one kilowatt-hour of energy. A television consuming 100 watts operating continuously for 10 hours uses one kilowatt-hour. A 40-watt electric appliance operating continuously for 25 hours uses one kilowatt-hour.

Electricity sales

[edit]

Electrical energy is typically sold to consumers in kilowatt-hours. The cost of running an electrical device is calculated by multiplying the device's power consumption in kilowatts by the operating time in hours, and by the price per kilowatt-hour. The unit price of electricity charged by utility companies may depend on the customer's consumption profile over time. Prices vary considerably by locality. In the United States prices in different states can vary by a factor of three.[11]

While smaller customer loads are usually billed only for energy, transmission services, and the rated capacity, larger consumers also pay for peak power consumption, the greatest power recorded in a fairly short time, such as 15 minutes. This compensates the power company for maintaining the infrastructure needed to provide peak power. These charges are billed as demand changes.[12] Industrial users may also have extra charges according to the power factor of their load.

Major energy production or consumption is often expressed as terawatt-hours (TWh) for a given period that is often a calendar year or financial year. A 365-day year equals 8,760 hours, so over a period of one year, power of one gigawatt equates to 8.76 terawatt-hours of energy. Conversely, one terawatt-hour is equal to a sustained power of about 114 megawatts for a period of one year.

Examples

[edit]

In 2020, the average household in the United States consumed 893 kWh per month.[13]

Raising the temperature of 1 litre of water from room temperature to the boiling point with an electric kettle takes about 0.1 kWh.

A 12 watt LED lamp lit constantly uses about 0.3 kW⋅h per 24 hours and about 9 kWh per month.

In terms of human power, a healthy adult male manual laborer performs work equal to about half a kilowatt-hour over an eight-hour day.[14]

Conversions

[edit]

To convert a quantity measured in a unit in the left column to the units in the top row, multiply by the factor in the cell where the row and column intersect.

Joule Watt-hour Kilowatt-hour Electronvolt Calorie
1 J = 1 kg⋅m2⋅s−2 = 1 2.77778 × 10−4 2.77778 × 10−7 6.241 × 1018 0.239
1 Wh = 3.6 × 103 1 0.001 2.247 × 1022 859.8
1 kWh = 3.6 × 106 1,000 1 2.247 × 1025 8.598 × 105
1 eV = 1.602 × 10−19 4.45 × 10−23 4.45 × 10−26 1 3.827 × 10−20
1 cal = 4.184 1.162 × 10−3 1.162 × 10−6 2.612 × 1019 1

Watt-hour multiples

[edit]
SI multiples of watt-hour (W⋅h)
Value Symbol Name
10−6 μW⋅h microwatt-hour
10−3 mW⋅h milliwatt-hour
100 W⋅h watt-hour
103 kW⋅h kilowatt-hour
106 MW⋅h megawatt-hour
109 GW⋅h gigawatt-hour
1012 TW⋅h terawatt-hour
1015 PW⋅h petawatt-hour

All the SI prefixes are commonly applied to the watt-hour: a kilowatt-hour is 1,000 Wh (kWh); a megawatt-hour is 1 million Wh (MWh); a milliwatt-hour is 1/1,000 Wh (mWh) and so on. The kilowatt-hour is commonly used by electrical energy providers for purposes of billing, since the monthly energy consumption of a typical residential customer ranges from a few hundred to a few thousand kilowatt-hours. Megawatt-hours (MWh), gigawatt-hours (GWh), and terawatt-hours (TWh) are often used for metering larger amounts of electrical energy to industrial customers and in power generation. The terawatt-hour and petawatt-hour (PWh) units are large enough to conveniently express the annual electricity generation for whole countries and the world energy consumption.

Distinction between kWh (energy) and kW (power)

[edit]

A kilowatt is a unit of power (rate of flow of energy per unit of time). A kilowatt-hour is a unit of energy. Kilowatt per hour would be a rate of change of power flow with time.

Work is the amount of energy transferred to a system; power is the rate of delivery of energy. Energy is measured in joules, or watt-seconds. Power is measured in watts, or joules per second.

For example, a battery stores energy. When the battery delivers its energy, it does so at a certain power, that is, the rate of delivery of the energy. The higher the power, the quicker the battery's stored energy is delivered. A higher power output will cause the battery's stored energy to be depleted in a shorter time period.

Annualized power

[edit]

Electric energy production and consumption are sometimes reported on a yearly basis, in units such as megawatt-hours per year (MWh/yr) gigawatt-hours/year (GWh/yr) or terawatt-hours per year (TWh/yr). These units have dimensions of energy divided by time and thus are units of power. They can be converted to SI power units by dividing by the number of hours in a year, about 8760 h/yr.

Thus, 1 GWh/yr = 1 GWh/8760 h ≈ 114.12 kW.

Misuse of watts per hour

[edit]

Many compound units for various kinds of rates explicitly mention units of time to indicate a change over time. For example: miles per hour, kilometres per hour, dollars per hour. Power units, such as kW, already measure the rate of energy per unit time (kW=kJ/s). Kilowatt-hours are a product of power and time, not a rate of change of power with time.

Watts per hour (W/h) is a unit of a change of power per hour, i.e. an acceleration in the delivery of energy. It is used to measure the daily variation of demand (e.g. the slope of the duck curve), or ramp-up behavior of power plants. For example, a power plant that reaches a power output of 1 MW from 0 MW in 15 minutes has a ramp-up rate of 4 MW/h.

Other uses of terms such as watts per hour are likely to be errors.[15][16]

[edit]

Several other units related to kilowatt-hour are commonly used to indicate power or energy capacity or use in specific application areas.

Average annual energy production or consumption can be expressed in kilowatt-hours per year. This is used with loads or output that vary during the year but whose annual totals are similar from one year to the next. For example, it is useful to compare the energy efficiency of household appliances whose power consumption varies with time or the season of the year. Another use is to measure the energy produced by a distributed power source. One kilowatt-hour per year equals about 114.08 milliwatts applied constantly during one year.

The energy content of a battery is usually expressed indirectly by its capacity in ampere-hours; to convert ampere-hour (Ah) to watt-hours (Wh), the ampere-hour value must be multiplied by the voltage of the power source. This value is approximate, since the battery voltage is not constant during its discharge, and because higher discharge rates reduce the total amount of energy that the battery can provide. In the case of devices that output a different voltage than the battery, it is the battery voltage (typically 3.7 V for Li-ion) that must be used to calculate rather than the device output (for example, usually 5.0 V for USB portable chargers). This results in a 500 mA USB device running for about 3.7 hours on a 2,500 mAh battery, not five hours.

The Board of Trade unit (B.T.U.)[17] is an obsolete UK synonym for kilowatt-hour. The term derives from the name of the Board of Trade which regulated the electricity industry until 1942 when the Ministry of Power took over.[18] This should not be confused with a British Thermal Unit (BTU) which is 1055 J.

In India, the kilowatt-hour is often simply called a unit of energy. A million units, designated MU, is a gigawatt-hour and a BU (billion units) is a terawatt-hour.[19][20]

See also

[edit]

References

[edit]
  1. ^ Thompson, Ambler and Taylor, Barry N. (2008). Guide for the Use of the International System of Units (SI) Archived 3 June 2016 at the Wayback Machine (Special publication 811). Gaithersburg, MD: National Institute of Standards and Technology. 12.
  2. ^ "Half-high dots or spaces are used to express a derived unit formed from two or more other units by multiplication.", Barry N. Taylor. (2001 ed.) The International System of Units. Archived 3 June 2016 at the Wayback Machine (Special publication 330). Gaithersburg, MD: National Institute of Standards and Technology. 20.
  3. ^ IEC Electropedia, Entry 131-11-58 Archived 14 March 2016 at the Wayback Machine
  4. ^ See for example: Wind Energy Reference Manual Part 2: Energy and Power Definitions Archived 26 November 2007 at the Wayback Machine Danish Wind Energy Association. Retrieved 9 January 2008; "Kilowatt-Hour (kWh)" Archived 2 March 2016 at the Wayback Machine BusinessDictionary.com. Retrieved 9 January 2008; "US Nuclear Power Industry" Archived 26 November 2007 at the Wayback Machine www.world-nuclear.org. Retrieved 9 January 2008; "Energy. A Beginners Guide: Making Sense of Units" Archived 26 November 2007 at the Wayback Machine Renew On Line (UK). The Open University. Retrieved 9 January 2008.
  5. ^ ASTM SI10-10, IEEE/ASTM SI 10 American National Standard for Metric Practice, ASTM International, West Conshohocken, PA, 2010, [www.astm.org] "The symbols for certain compound units of electrical power engineering are usually written without separation, thus: watthour (Wh), kilowatthour (kWh), voltampere (VA), and kilovoltampere (kVA)"
  6. ^ a b c "The International System of Units (SI)" (PDF). International Bureau of Weights and Measures (BIPM). 2019. p. 147. Retrieved 7 April 2020.
  7. ^ Standard for the Use of the International System of Units (SI): The Modern Metric System. (1997). (IEEE/ASTM SI 10-1997). New York and West Conshohocken, PA: Institute of Electrical and Electronics Engineers and ASTM. 15.
  8. ^ "10.57: Units derived from SI base units". The Chicago Manual of Style (17 ed.). Chicago: University of Chicago Press. 2017. Retrieved 1 April 2020.
  9. ^ "Guide for the Use of the International System of Units (SI)" (PDF). National Institute of Standards and Technology. 2008. Retrieved 6 April 2020. Reference [4: ISO 31-0] suggests that if a space is used to indicate units formed by multiplication, the space may be omitted if it does not cause confusion. This possibility is reflected in the common practice of using the symbol kWh rather than kW⋅h or kW h for the kilowatt-hour. Nevertheless, this Guide takes the position that a half-high dot or a space should always be used to avoid possible confusion;
  10. ^ "Electric Vehicles: Learn More About the New Label". fueleconomy.gov. US Department of energy. Retrieved 10 August 2014.
  11. ^ Average Price of Electricity to Ultimate Customers by End-Use Sector, U.S. Energy Information Administration, April 2018
  12. ^ "Understanding Electric Demand" Archived 6 June 2016 at the Wayback Machine, National Grid
  13. ^ "How much electricity does an American home use?". U.S. Energy Information Administration. 7 October 2021. Retrieved 11 June 2022.
  14. ^ Eugene A. Avallone et al., (ed), Marks' Standard Handbook for Mechanical Engineers 11th Edition , Mc-Graw Hill, New York 2007 ISBN 0-07-142867-4 page 9-4
  15. ^ Woofenden, Ian (5 October 2009). Wind Power For Dummies. John Wiley & Sons. p. 48. ISBN 978-0-470-49637-4. Much too often, I hear people say something like ... 'watts per hour'...
  16. ^ Home Power. Electron Connection. 2007. Watts per hour. This nonsensical phrase tops my electrical terminology pet peeve list.
  17. ^ E. M. Kirkpatrick, ed. (1983). Chambers 20th Century Dictionary (New ed.). Edinburgh: Chambers. p. 137. ISBN 0550102345.
  18. ^ "The Board of Trade 1621-1970". Department for Business Innovation and Skills. Archived from the original on 4 March 2010.
  19. ^ "Get enlightened about electricity". The Financial Express. 20 December 2004. Archived from the original on 8 September 2012. Retrieved 29 November 2009.
  20. ^ "BHEL manufactured units generate record power". The Hindu. Press Trust of India. 24 July 2008. Archived from the original on 7 November 2012. Retrieved 29 November 2009.