- Yamamoto, Myong Hwa;
- Maehara, Akiko;
- Stone, Gregg W;
- Kini, Annapoorna S;
- Brilakis, Emmanouil S;
- Rizik, David G;
- Shunk, Kendrick;
- Powers, Eric R;
- Tobis, Jonathan M;
- Maini, Brijeshwar S;
- Dixon, Simon R;
- Goldstein, James A;
- Petersen, John L;
- Généreux, Philippe;
- Shah, Priti R;
- Crowley, Aaron;
- Nicholls, Stephen J;
- Mintz, Gary S;
- Muller, James E;
- Weisz, Giora
Background
Autopsy studies suggest that implanting stents in lipid-rich plaque (LRP) may be associated with adverse outcomes.Objectives
The purpose of this study was to evaluate the association between LRP detected by near-infrared spectroscopy (NIRS) and clinical outcomes in patients with coronary artery disease treated with contemporary drug-eluting stents.Methods
In this prospective, multicenter registry, NIRS was performed in patients undergoing coronary angiography and possible percutaneous coronary intervention (PCI). Lipid core burden index (LCBI) was calculated as the fraction of pixels with the probability of LRP >0.6 within a region of interest. MaxLCBI4mm was defined as the maximum LCBI within any 4-mm-long segment. Major adverse cardiac events (MACE) included cardiac death, myocardial infarction, definite or probable stent thrombosis, or unplanned revascularization or rehospitalization for progressive angina or unstable angina. Events were subcategorized as culprit (treated) lesion-related, nonculprit (untreated) lesion-related, or indeterminate.Results
Among 1,999 patients who were enrolled in the COLOR (Chemometric Observations of Lipid Core Plaques of Interest in Native Coronary Arteries Registry), PCI was performed in 1,621 patients and MACE occurred in 18.0% of patients, of which 8.3% were culprit lesion-related, 10.7% were nonculprit lesion-related, and 3.1% were indeterminate during 2-year follow-up. Complications from NIRS imaging occurred in 9 patients (0.45%), which resulted in 1 peri-procedural myocardial infarction and 1 emergent coronary bypass. Pre-PCI NIRS imaging was obtained in 1,189 patients, and the 2-year rate of culprit lesion-related MACE was not significantly associated with maxLCBI4mm (hazard ratio of maxLCBI4mm per 100: 1.06; 95% confidence interval: 0.96 to 1.17; p = 0.28) after adjusting clinical and procedural factors.Conclusions
Following PCI with contemporary drug-eluting stents, stent implantation in NIRS-defined LRPs was not associated with increased periprocedural or late adverse outcomes compared with those without significant lipid.