Electrocardiography - Cardiovascular Disorders - MSD Manual Professional Edition (2024)

A standard 12-lead ECG represents only a single brief period of cardiac activity; enhanced techniques can provide additional information.

Additional precordial leads

Additional precordial leads are used to help diagnose

Right-sided leads are placed across the right side of the chest to mirror standard left-sided leads. They are labeled V1R to V6R; sometimes only V4R is used, because it is the most sensitive for right ventricular myocardial infarction.

Additional left-sided leads can be placed in the 5th intercostal space, with V7 at the posterior axillary line, V8 at the midscapular line, and V9 at the left border of the spine. These leads are rarely used but may help diagnose a true posterior myocardial infarction.

Esophageal lead

An esophageal lead is much closer to the atria than surface leads; it is an option when the presence of P waves on a standard recording is uncertain and when detecting atrial electrical activity is important, as when atrial or ventricular origin of wide-complex tachycardia must be differentiated or when atrioventricular dissociation is suspected. An esophageal lead may also be used to monitor intraoperative myocardial ischemia or to detect atrial activity during cardioplegia. The lead is placed by having the patient swallow an electrode, which is then connected to a standard ECG machine, often in the lead II port.

Signal averaging

Signal averaging of QRS waveforms creates a digital composite of several hundred cardiac cycles to detect high-frequency, low-amplitude potentials and microcurrents at the terminal part of the QRS complex. These findings represent areas of slow conduction through abnormal myocardium, indicating increased risk of reentrant ventricular tachycardia.

Signal-averaged ECG is still largely a research technique but is occasionally used to assess risk of sudden cardiac death (eg, in patients with known significant heart disease). It seems most useful in identifying patients at low risk of sudden death. Its value for identifying patients at high risk of sudden death has not been established.

Signal averaging is also being investigated in various other cardiac disorders, ranging from the post-myocardial infarction state and cardiomyopathies to Brugada syndrome and ventricular aneurysms, and to assess efficacy of surgery to correct the arrhythmia. This technique may also be useful for assessing the proarrhythmic effects of antiarrhythmic drugs and for detecting rejection of heart transplants.

Signal averaging of P waves is being studied as a way to identify patients at risk of atrial fibrillation.

Continuous ST-segment monitoring

This type of monitoring is used for early detection of ischemia and serious arrhythmias. Monitoring can be automated (dedicated electronic monitoring units are available) or done clinically using serial ECGs. Applications include emergency department monitoring of patients with crescendo angina, evaluation after percutaneous intervention, intraoperative monitoring, and postoperative care.

QT dispersion

QT dispersion (the difference between the longest and shortest QT intervals on a 12-lead ECG) has been proposed as a measure of myocardial repolarization heterogeneity. Increased dispersion (≥ 100 millisecond) suggests electrically heterogeneous myocardium caused by ischemia or fibrosis, with increased risk of reentrant arrhythmias and sudden death. QT dispersion predicts mortality risk but is not widely measured because measurement error is common, values in patients with and without disease overlap substantially, there is no reference standard, and other validated risk predictors are available.

Heart rate variability

This measurement reflects the balance between sympathetic and parasympathetic (vagal) input to the heart. Decreased variability suggests decreased vagal input and increased sympathetic input, which predict increased risk of arrhythmias and mortality. The most common measure of variability is the mean of the standard deviations of all normal R-R intervals in a 24-hour ECG recording.

Heart rate variability is used primarily in research. Evidence suggests that it provides useful information about left ventricular dysfunction after myocardial infarction, heart failure, and hypertrophic cardiomyopathy. Most Holter monitors have software that measures and analyzes heart rate variability, but clinical utility is currently uncertain.

Holter monitor

Holter monitoring is continuous monitoring and recording of the ECG for 24 to 48 hours. It is useful for evaluating intermittent arrhythmias and, secondarily, for detecting hypertension. The Holter monitor is portable, enabling patients to participate in normal daily activities; it may also be used for sedentary hospitalized patients if automated monitoring is unavailable. Patients are asked to record symptoms and activities so that they may be correlated with events on the monitor. The Holter monitor does not automatically analyze the ECG data; a physician does so at a later date.

Event recorder

Event recorders are worn for up to 30 days and can detect infrequent rhythm disturbances that 24-hour Holter monitoring may miss. The recorder may operate continuously or also be activated by the patient when symptoms occur. A memory loop enables information to be stored for seconds or minutes before and after activation. The patient can transmit ECG data by telephone or satellite to be read by a physician; some recorders automatically transmit serious events. If patients have serious events (eg, syncope) at intervals of > 30 days, an event recorder may be placed subcutaneously (implantable loop recorder); it can be activated by a small magnet. Battery life for subcutaneous recorders is several years.

Wireless adhesive monitor

Another option for single-channel rhythm monitoring is a small, adhesive, water-resistant, wireless, and disposable device worn on the chest. One type of this device continuously records cardiac rhythms for up to 2 weeks. Another similar device functions as an event recorder; a patient pushes a button on the device when experiencing any potential arrhythmia-related symptoms (eg, palpitations, dizziness) to record stored ECG data 45 seconds before the event plus 15 seconds after the event. However, unlike with event recorders, automated, real-time reporting is not available.

Smartwatches with ECG capability

Several consumer smartwatches take ECG measurements from the wrist. Smartwatches have the potential to detect arrhythmias in real time, and their usefulness in this area is under investigation.

Electrocardiography - Cardiovascular Disorders - MSD Manual Professional Edition (2024)

References

Top Articles
Latest Posts
Recommended Articles
Article information

Author: Edmund Hettinger DC

Last Updated:

Views: 6163

Rating: 4.8 / 5 (78 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Edmund Hettinger DC

Birthday: 1994-08-17

Address: 2033 Gerhold Pine, Port Jocelyn, VA 12101-5654

Phone: +8524399971620

Job: Central Manufacturing Supervisor

Hobby: Jogging, Metalworking, Tai chi, Shopping, Puzzles, Rock climbing, Crocheting

Introduction: My name is Edmund Hettinger DC, I am a adventurous, colorful, gifted, determined, precious, open, colorful person who loves writing and wants to share my knowledge and understanding with you.