Description
The Procon Probe Loop Detector Kit can measure the magnetic field in 3 axis, namely the X, Y, and Z axis. Each axis can be individually enabled to optimise vehicle detection. Normally all 3 axis would be enabled.
The MD102 probe can be buried in the road surface underneath the vehicle, alongside the vehicle or can be mounted above the ground next to the passage of the vehicle. The probe can be used to produce a pulse output or a presence out. The presence out will detect the vehicle indefinitely.
The MD102C is a control unit which enables configuration and testing of the MD102. DIP switches are used for configuration and LED’s are used for visual indications of the operation of the probe. A relay output switches ON when a vehicle is detected. The MD102 has been designed for parking and access control applications and is a cost-effective solution for detecting vehicles in order to facilitate the automatic opening of security gates. It requires a minimal amount of cutting in the road surface.
- Easy to install – no need to cut induction loops
- Quality brand, guaranteed reliability
- 15m Cable
- Easy to set up controller with LED detection indicator Can be used for presence and pulse
Technical information about the Procon Probe Loop Detector Kit:
- 12/24Vdc Power input
- Adjustable sensitivity
- Adjustable detection zone, X,Y and Z axis
- Can be installed underground or on static post/side of a driveway
- 5 Minute presence reset
- NOTE: If post mounted needs to be less than 1500mm from passing vehicle
To see our full range of induction loops click here
For more information for the manufacturer please click here
Anonymous (verified owner) –
Super quick delivery
steven Ford (verified owner) –
What an excellent product. Very impressed. Will buy again!
Malcolm Bloomfield (verified owner) –
Jon Haines (verified owner) –
Great service, very helpful and quick delivery.
Philip R. (verified owner) –
Product does the job well (much better than an induction loop). Easy to use the probe and controller to replace a failed induction loop. Cable can be extended (with care) if the probe needs to be a long way from the controller location (we used direct burial cat 6 with a pair for data, a pair for power, a single for the pulse, and the remaining 3 wires to carry the ground to extend the cable for out application).
If using the controller all 5 (plus earth) cables need to be connected or it will show a fault. However, it is possible to use the probe directly (3 wires plus earth) if you had another suitable controller or relay/logic to capture the pulse generated on the white wire when a vehicle goes over the probe.
Jason Whittaker (verified owner) –
Great service yet again
Anonymous (verified owner) –
Trevor Gibbs (verified owner) –
Malcolm Bloomfield (verified owner) –
Adam (verified owner) –
So much easier than a loop to install, great.
Robert S. (verified owner) –
Great service, advice and price, have used this company for many years now and will do for many more, cheers.
dale buckwell (verified owner) –
5 star service as always
Mark L. (verified owner) –
Quick delivery, thanks guys 👍