£250.00
Comprehensive guidance on how to provide safe and compliant temporary edge protection for flat and sloping roofs with an angle of up to 10°.
TG1:22 provides guidance on the requirements for Class A type edge protection, constructed with tube and fittings, in compliance with BS EN 13374:2013+A1:2018, together with the basic elements of construction. This includes edge protection for flat and sloping roofs up to an angle of 10 degrees as well as for open floors. This document includes 15 No. generic design drawings, which may be used without the need for a bespoke design, provided that environmental conditions and roof/floor structures are suitable.
This guidance is available for pdf download only. Please note it is NOT an add-on to the TG20:21 ePortal and does not create compliance sheets. For a more detailed summary of TG1:22 please click here.
In order to be able to visually identify EN74 certified couplers, this guidance document identifies the specification and minimum markings to be found on all EN74-1:2005 and EN74-1:2022 scaffold couplers, together with brief details regarding the differences between the two standards. This product is available in PDF format only.
2 pages
Scaffold board nailplates are specially stamped toothed strips of galvanised steel that can be applied to new or used boards to prevent or to repair existing end splits. Experience gained over many years by the scaffold industry indicates that the service life of a board can be substantially extended if nailplates are fitted. This revised and updated version contains additional information and guidance on the specification and fitting of nailplates.
This document provides best practice for the use and application of steel and aluminium prefabricated beams. Included is information regarding beam types, uses, joints, handling, transportation and storage. Due to the wide variation of beams available on the market, it has not been possible to include individual load capacities, but information regarding tension and compression chords, correct methods of lacing, bracing and connections to standards and puncheons provides vital information to ensure that beams are correctly installed to support their maximum safe working loads. This guidance is available for pdf download only.
This guidance explains the differences between ‘supplementary’ and ‘check’ couplers and gives typical design applications where high coupler forces could be expected and where additional loadbearing capacity to connections may be required. It also contains guidance on coupler configurations and expected safe working loads (SWLs) where supplementary couplers are used. To ensure that SWL values are as accurate as possible, data provided within this document is based on practical testing rather than calculation. 2 pages
Please enter a postcode to search for a member:
Please complete the fields below: