Follow
David Holder
David Holder
Professor of Biophysics and Clinical Neurophysiology, University College London
Verified email at ucl.ac.uk - Homepage
Title
Cited by
Cited by
Year
Electrical impedance tomography: methods, history and applications
A Adler, D Holder
CRC Press, 2021
17632021
Three-dimensional electrical impedance tomography of human brain activity
T Tidswell, A Gibson, RH Bayford, DS Holder
NeuroImage 13 (2), 283-294, 2001
2562001
Electrical impedance tomography: Methods
DS Holder
history and applications 453, 2005
2432005
Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method
AP Bagshaw, AD Liston, RH Bayford, A Tizzard, AP Gibson, AT Tidswell, ...
NeuroImage 20 (2), 752-764, 2003
2242003
A review of errors in multi-frequency EIT instrumentation
A McEwan, G Cusick, DS Holder
Physiological measurement 28 (7), S197, 2007
1922007
Imaging fast electrical activity in the brain with electrical impedance tomography
KY Aristovich, BC Packham, H Koo, GS Dos Santos, A McEvoy, ...
NeuroImage 124, 204-213, 2016
1792016
Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke, development of …
A Romsauerova, A McEwan, L Horesh, R Yerworth, RH Bayford, ...
Physiological measurement 27 (5), S147, 2006
1722006
Electrical impedance tomography method and apparatus
KG Boone, DS Holder
US Patent 5,919,142, 1999
1711999
Clinical and physiological applications of electrical impedance tomography
D Holder
CRC Press, 1993
1661993
Use of anisotropic modelling in electrical impedance tomography; description of method and preliminary assessment of utility in imaging brain function in the adult human head
JFPJ Abascal, SR Arridge, D Atkinson, R Horesh, L Fabrizi, M De Lucia, ...
Neuroimage 43 (2), 258-268, 2008
1492008
Design and calibration of a compact multi-frequency EIT system for acute stroke imaging
A McEwan, A Romsauerova, R Yerworth, L Horesh, R Bayford, D Holder
Physiological measurement 27 (5), S199, 2006
1462006
Current approaches to analogue instrumentation design in electrical impedance tomography
KG Boone, DS Holder
Physiological measurement 17 (4), 229, 1996
1361996
Multi-frequency EIT system with radially symmetric architecture: KHU Mark1
TI Oh, EJ Woo, D Holder
Physiological measurement 28 (7), S183, 2007
1272007
Electrical impedance tomography (EIT) of brain function
DS Holder
Brain topography 5, 87-93, 1992
1241992
A versatile and reproducible multi-frequency electrical impedance tomography system
J Avery, T Dowrick, M Faulkner, N Goren, D Holder
Sensors 17 (2), 280, 2017
1172017
Electrical impedance tomography spectroscopy (EITS) for human head imaging
RJ Yerworth, RH Bayford, B Brown, P Milnes, M Conway, DS Holder
Physiological measurement 24 (2), 477, 2003
1142003
Generating accurate finite element meshes for the forward model of the human head in EIT
A Tizzard, L Horesh, RJ Yerworth, DS Holder, RH Bayford
Physiological measurement 26 (2), S251, 2005
1122005
Multifrequency electrical impedance tomography using spectral constraints
E Malone, GS Dos Santos, D Holder, S Arridge
IEEE transactions on medical imaging 33 (2), 340-350, 2013
1082013
Imaging cerebral haemorrhage with magnetic induction tomography: numerical modelling
M Zolgharni, PD Ledger, DW Armitage, DS Holder, H Griffiths
Physiological measurement 30 (6), S187, 2009
1012009
Factors limiting the application of electrical impedance tomography for identification of regional conductivity changes using scalp electrodes during epileptic seizures in humans
L Fabrizi, M Sparkes, L Horesh, JFPJ Abascal, A McEwan, RH Bayford, ...
Physiological measurement 27 (5), S163, 2006
952006
The system can't perform the operation now. Try again later.
Articles 1–20