A low-profile supercapacitor-based normal and shear force sensor
Y Zhang, AS Sezen, R Rajamani - IEEE Sensors Journal, 2020 - ieeexplore.ieee.org
This paper focuses on the development of a thin normal-shear force sensor based on the
use of a supercapacitive sensing mechanism. The sensor has a quad structure with four …
use of a supercapacitive sensing mechanism. The sensor has a quad structure with four …
A four degree of freedom MEMS microgripper with novel bi-directional thermal actuators
MA Greminger, AS Sezen… - 2005 IEEE/RSJ …, 2005 - ieeexplore.ieee.org
A four degree of freedom thermally actuated MEMS microgripper is presented in this paper.
Each jaw of the microgripper has independent x and y degrees of freedom. These extra …
Each jaw of the microgripper has independent x and y degrees of freedom. These extra …
A novel real-time capacitance estimation methodology for battery-less wireless sensor systems
HS Kim, S Sivaramakrishnan, AS Sezen… - IEEE Sensors …, 2010 - ieeexplore.ieee.org
This paper presents a novel method to read a passive capacitive sensor in telemetry by
using inductive coupling. While classical inductive coupling approaches measure sensor …
using inductive coupling. While classical inductive coupling approaches measure sensor …
Flexible distributed pressure sensing strip for a urethral catheter
…, R Rajamani, G Timm, AS Sezen - Journal of …, 2015 - ieeexplore.ieee.org
A multi-sensor flexible strip is developed for a urethral catheter to measure distributed
pressure in a human urethra. The developed sensor strip has important clinical applications in …
pressure in a human urethra. The developed sensor strip has important clinical applications in …
Bodily distalization of molars with absolute anchorage
A Keles, N Erverdi, S Sezen - The Angle Orthodontist, 2003 - meridian.allenpress.com
Palatal implants have been used over the last two decades to eliminate headgear wear and
to establish stationary anchorage. In this case report, the stability of a palatal implant for …
to establish stationary anchorage. In this case report, the stability of a palatal implant for …
Effect of blood and saliva contamination on bond strength of brackets bonded with a protective liquid polish and a light-cured adhesive
K Sayinsu, F Isik, S Sezen, B Aydemir - American Journal of Orthodontics …, 2007 - Elsevier
Introduction: The application of a polymer coating to the labial enamel tooth surface before
bonding can help keep white spot lesions from forming. Previous studies evaluating the …
bonding can help keep white spot lesions from forming. Previous studies evaluating the …
[HTML][HTML] Note: Development of leg size sensors for fluid accumulation monitoring
…, R Rajamani, L Alexander, A Serdar Sezen - Review of Scientific …, 2016 - pubs.aip.org
A number of diseases can lead to fluid accumulation and swelling in the lower leg. Early
detection of leg swelling can be used to effectively predict potential health risks and allows for …
detection of leg swelling can be used to effectively predict potential health risks and allows for …
Magnetic sensor for configurable measurement of tension or elasticity with validation in animal soft tissues
…, R Rajamani, M Ahmadi, AS Sezen… - IEEE Transactions …, 2014 - ieeexplore.ieee.org
This paper presents a novel Hall-effect-based magnetic sensor for handheld measurement
of either elasticity or tension in soft tissues. A theoretical model is developed for the …
of either elasticity or tension in soft tissues. A theoretical model is developed for the …
Development of an interactive visual planar mechanism synthesis and analysis program by using delphi object oriented programming environment
AS Sezen - 2001 - open.metu.edu.tr
Simulation of engineering problems plays a crucial role in understanding them well and
solving them efficiently. In geotechnical engineering, problems first need a very good …
solving them efficiently. In geotechnical engineering, problems first need a very good …
A super-capacitive pressure sensor for a urethral catheter
…, R Rajamani, G Timm, AS Sezen - 2018 40th Annual …, 2018 - ieeexplore.ieee.org
Urinary incontinence can be due to neuromuscular or structural problems in either the bladder
or the urethra. Urodynamics is often used to analyze the patient-specific cause of urinary …
or the urethra. Urodynamics is often used to analyze the patient-specific cause of urinary …