single-rb.php

JRM Vol.20 No.3 pp. 456-465
doi: 10.20965/jrm.2008.p0456
(2008)

Paper:

Development of the Breast Pump with a Baby-Like Peristaltic Motion

Hiroshi Kobayashi*, Toshiaki Tsuji*, Yukinari Awano**,
Katsumi Mizuno***, Hiroshi Kawamura****, Zenichi Onuki*****,
and Aki Ishimaru*****

* Faculty of Engineering, Tokyo University of Science, 1-14-6 Kudankita, Chiyoda-ku, Tokyo 102-1073, Japan

**Graduate School of Engineering, Tokyo University of Science, 1-14-6 Kudankita, Chiyoda-ku, Tokyo 102-1073, Japan

***Department of Pediatrics, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo 142-8666, Japan

****Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-0022, Japan

*****Joso Laboratory, Pigeon Corporation, 6-20-4 Kinunodai, Tsukubamirai, Ibaragi 300-2495, Japan

Received:
January 8, 2008
Accepted:
January 8, 2008
Published:
June 20, 2008
Keywords:
breast pump, baby-like motion, cam mechanism, medical and welfare assistance
Abstract
Because of change in woman’s place in society, the number of working woman is growing and the demand of the breast pump is increasing as well. Commercial product of the breast pump is applying only negative pressure for sucking and many users feel a pain for a long term use. While a baby is using peristaltic motion as the result of tongue and jaw action in addition to suction. In this research, therefore the breast pump with a baby-like motion is developed. In order to realize baby-like peristaltic motion, cam mechanism is applied. Also for producing negative pressure, crank mechanism is utilized. As the result, it turns out that the breast pump developed is realized the same peristaltic motion and suction pattern as a baby.

This paper is the full translation from the transactions of JSME Vol.73, No.730.
Cite this article as:
H. Kobayashi, T. Tsuji, Y. Awano, K. Mizuno, H. Kawamura, Z. Onuki, and A. Ishimaru, “Development of the Breast Pump with a Baby-Like Peristaltic Motion,” J. Robot. Mechatron., Vol.20 No.3, pp. 456-465, 2008.
Data files:
References
  1. [1] T. Iguchi, et al., “Female’s <body and heart> easy medicine Women Medical,” Shougakukan Inc., First printed, pp. 116-119, 2003. (in Japanese).
  2. [2] L. R. Mitoras, et al., “Effect of Vacuum Profile on Breast Milk Expression Using an Electric Breast Pump,” J Hum Lact, 18(4), pp. 353-360, 2002.
  3. [3] J. C. Kent, “Response of Breasts to Different Stimulation Patterns of an Electric Breast Pump,” J Hum Lact, 19(2), pp. 179-186, 2003.
  4. [4] D. T. Ramsay, et al., “The Use of Ultrasound to Characterize Milk Ejection in Women Using an Electric Breast Pump,” J Hum Lact, 21(4), pp. 421-428, 2005.
  5. [5] K. Mizuno and K. Kani, “Sipping/lapping is a safe alternative feeding method to suckling for preterm infants,” Acta Padiatrica, 94, pp. 574-580, 2005.
  6. [6] M. S. Fewtrell, et al., “Randomized Trial Comparing the Efficacy of a Novel Manual Breast PumpWith a Standard Electric Breast Pump in Mothers Who Delivered Preterm Infants,” PEDIATRICS, 107(6), pp. 1291-1297, 2001.
  7. [7] K. Iwayama and M. Eishima, “Neonatal sucking behavior and its development until 14 months,” Early Hum Dev. Jan, 3;47(1), pp. 1-9, 1997.
  8. [8] K. Ogawa and K. Kato, “New mechanical engineering series 1 mechanism,” Morikita Publishing Co., 19th edition, pp. 36-37, 1985. (in Japanese).
  9. [9] D. T. Ramsay, et al., “Ultrasound Imaging of Milk Ejection in the Breast of Lactating Women,” PEDIATRICS, 113(2), pp. 361-367, 2004.

*This site is desgined based on HTML5 and CSS3 for modern browsers, e.g. Chrome, Firefox, Safari, Edge, Opera.

Last updated on Nov. 04, 2024