This is an old revision of this page, as edited by WikiCleanerBot (talk | contribs) at 12:57, 13 October 2020 (v2.03b - Bot T20 CW#61 - WP:WCW project (Reference before punctuation)). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

Cogging torque of electrical motors is the torque due to the interaction between the permanent magnets of the rotor and the stator slots of a Permanent Magnet (PM) machine. It is also known as detent or 'no-current' torque. This torque is position dependent and its periodicity per revolution depends on the number of magnetic poles and the number of teeth on the stator. Cogging torque is an undesirable component for the operation of such a motor. It is especially prominent at lower speeds, with the symptom of jerkiness. Cogging torque results in torque as well as speed ripple; however, at high speed the motor moment of inertia filters out the effect of cogging torque.

Reducing the cogging torque

A summary of techniques used for reducing cogging torque:[1]

  • Skewing stator stack or magnets
  • Using fractional slots per pole
  • Optimizing the magnet pole arc or width[2]

Almost all the techniques used against cogging torque also reduce the motor counter-electromotive force and so reduce the resultant running torque.

A slotless and coreless permanent magnet motor does not have any cogging torque.

Footnotes and References

  1. ^ "Cogging Torque Reduction in a Permanent Magnet Wind Turbine Generator" (PDF).
  2. ^ Flankl, Michael; Tüysüz, Arda; Kolar, Johann W. (December 2017). "Cogging Torque Shape Optimization of an Integrated Generator for Electromechanical Energy Harvesting" (PDF). IEEE Transactions on Industrial Electronics. doi:10.1109/TIE.2017.2733441. Archived from the original (PDF) on 2018-02-02. Retrieved 2018-02-01. {{cite journal}}: Unknown parameter |lastauthoramp= ignored (|name-list-style= suggested) (help)

See also