The water-cooled furnace wall is of a water-cooled sealed tube structure, consisting of 26 pieces, uniformly distributed on the inner wall of the upper furnace shell. The top cover of the eccentric area is also of a water-cooled sealed tube structure, and ball valves are installed for both inlet and outlet water. The total inlet water has a pressure sensing instrument and temperature detection, and the total inlet water pressure and temperature can be displayed on the computer.
The upper and lower furnace shells are connected by a pin shaft for easy disassembly. The furnace body has solid lifting lugs, so the furnace shell can be lifted out or in as a whole. The design of the furnace door frame has taken into account the space for operating the furnace door with a carbon oxygen lance. EBT steel tapping opening and closing adopts hydraulic drive, and the furnace door opening and closing adopts hydraulic drive.
Type | Inner Dia of Furnace Shell (mm) | Rated/Max(t) |
HX-0.5 | 2000 | 0.5/1 |
HX-1.5 | 2200 | 1.5/3 |
HX-3 | 2700 | 3/8 |
HX-5 | 3200 | 5/12 |
HX-10 | 3500 | 10/16 |
HX-15 | 3700 | 15/20 |
HX-20 | 4000/4200 | 20/32 |
HX-30 | 4600 | 30/45 |
HX-40 | 5000 | 40/50 |
HX-50 | 5000 | 50/60 |
HX-60 | 5500 | 60/80 |
HX-80 | 6100 | 80/100 |
HX-100 | 6400 | 100/125 |