A Modified Dickson Charge Pump Circuit with High Efficiency and High Output Voltage
Duk-Hyung LEEDaejeong KIMHo-Jun SONGKyeong-Sik MIN
Author information
JOURNAL RESTRICTED ACCESS

2008 Volume E91.C Issue 2 Pages 228-231

Details
Abstract

A power-efficient Dickson-based charge pump circuit is proposed and verified in this paper. Using a PMOS transfer switch in the new circuit solves the problem of the output voltage loss and its body control switch can suppress the parasitic bipolar action. Comparing this new one with the conventional circuit, the new circuit generates output voltage as high as 2.9VDD while the conventional one only 2VDD. For their efficiency values, the new circuit has better efficiency than the conventional one by as much as 14.5% with the area overhead of 12.2% using 3.5-μm and 40-V CMOS high-voltage process.

Content from these authors
© 2008 The Institute of Electronics, Information and Communication Engineers