Paper
13 March 2013 CT colonography: inverse-consistent symmetric registration of prone and supine inner colon surfaces
Holger R. Roth, Jamie R. McClelland, Marc Modat, Thomas E. Hampshire, Darren J. Boone, Emma Helbren, Andrew Plumb, Mingxing Hu, Sebastien Ourselin, Steve Halligan, David J. Hawkes
Author Affiliations +
Proceedings Volume 8669, Medical Imaging 2013: Image Processing; 866912 (2013) https://doi.org/10.1117/12.2007004
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
CT colonography interpretation is difficult and time-consuming because fecal residue or fluid can mimic or obscure polyps, leading to diagnostic errors. To compensate for this, it is normal practice to obtain CT data with the patient in prone and supine positions. Repositioning redistributes fecal residue and colonic gas; fecal residue tends to move, while fixed mural pathology does not. The cornerstone of competent interpretation is the matching of corresponding endoluminal locations between prone and supine acquisitions. Robust and accurate automated registration between acquisitions should lead to faster and more accurate detection of colorectal cancer and polyps. Any directional bias when registering the colonic surfaces could lead to incorrect anatomical correspondence resulting in reader error. We aim to reduce directional bias and so increase robustness by adapting a cylindrical registration algorithm to penalize inverse-consistency error, using a symmetric optimization. Using 17 validation cases, the mean inverse-consistency error was reduced significantly by 86%, from 3.3 mm to 0.45 mm. Furthermore, we show improved alignment of the prone and supine colonic surfaces, evidenced by a reduction in the mean-of-squared-differences by 43% overall. Mean registration error, measured at a sparse set of manually selected reference points, remained at the same level as the non-symmetric method (no significant differences). Our results suggest that the inverse-consistent symmetric algorithm performs more robustly than non-symmetric implementation of B-spline registration.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Holger R. Roth, Jamie R. McClelland, Marc Modat, Thomas E. Hampshire, Darren J. Boone, Emma Helbren, Andrew Plumb, Mingxing Hu, Sebastien Ourselin, Steve Halligan, and David J. Hawkes "CT colonography: inverse-consistent symmetric registration of prone and supine inner colon surfaces", Proc. SPIE 8669, Medical Imaging 2013: Image Processing, 866912 (13 March 2013); https://doi.org/10.1117/12.2007004
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image registration

Colon

Virtual colonoscopy

Colorectal cancer

Photonic integrated circuits

Visualization

Diagnostics

Back to Top