Paper
7 March 2014 Effects of powder morphology and particle size on CT number estimates
Jeffrey S. Kallman, Sabrina dePiero, Stephen Azevedo, Harry E. Martz Jr.
Author Affiliations +
Proceedings Volume 9020, Computational Imaging XII; 90200K (2014) https://doi.org/10.1117/12.2048876
Event: IS&T/SPIE Electronic Imaging, 2014, San Francisco, California, United States
Abstract
We performed experiments and data analysis to determine how powder morphology and particle size affect X-ray attenuation (CT number or CTN). These experiments were performed on a CT system with an isotropic resolution of (0.15 mm)3, and an endpoint energy of 160kV. Powders with effective atomic number (Ze) within ±0.2 of water were found to have CTN more directly related to electron density than to bulk physical density. Variations in mean particle size ranging between 2 μm and 44 μm were found to have no effect on specimen mean CTN.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.