The Detection of Prenatal Growth using Artificial Neural Network
DOI:
https://doi.org/10.15837/ijccc.2023.3.4255Keywords:
Ultrasound images, Amniotic fluid volumes, Oligohydramnios, polyhydramniosAbstract
Amniotic fluid abnormalities are caused by perinatal death and morbidity. Foetal growth and development are examples of parameters that must be accessible. Ultrasound technology is used to make an image of the uterus. Main aim of this work is to reduce the mortality and morbidity. Because, every year, 30 million new-borns have growth limitation, and there is a link between oligohydramnios (lack of amniotic fluid) and perinatal death. AFI can be measured with the assistance of ultrasound images. It is divided into four equal quadrants, with the Amniotic Fluid Index being the average of these quadrants (AFI). The performance of an Adaptive Neuro-Fuzzy Inference classifier is used for classification techniques. For the implementation of this research uses convolution neural network. During the second and third trimesters of pregnancy, this method is used to detect malformations using deep learning techniques. This strategy aims to reduce diagnostic time and risk factors in earlier stages of pregnancy.
References
Sabrina, Q.R.; (2013), Amniotic Fluid Volume Assessment Using the Single Deepest Pocket Technique in Bangladesh, Journal of Medical Ultrasound,21(2), 202-206,2013
https://doi.org/10.1016/j.jmu.2013.10.011
Swati, B.; Sujata, B.; Jyoti, B., (2018), Assessment of Perinatal Outcome using Amniotic Fluid Index and Color of Liquor: A Prospective Study, International Journal of Medical and Health Research, 4(3), 77-79, 2018.
Payam, Z.; Abdoljalil, A.; Hasan, D.; (2017), Early Detection of Breast Cancer using Optimized ANFIS and Features Selection, In 9th International Conference on Computational Intelligence and Communication Networks, Girne, Cyprus, 39-42, 2017.
Athira, P. K.; Linda, S. M.; (2015), Fetal Anomaly Detection in Ultrasound Image, International Journal of Computer Applications, 129(9), 1-4, 2015.
https://doi.org/10.5120/ijca2015906587
Smitha, P.; Shaji, L.; Mini, M. G.; (2011), A Review of Medical Image Classification Techniques, International Conference on VLSI, Communication and Instrumentation, Bandung, Indonesia, 34-38, 2011.
Everett. F. M.; Dorota, A. D.; Suneet, P. C.; Jennifer Moses, John, P. N.; John. C. M.; (2004), Is There a Relationship to Dye Determined or Ultrasound Estimated Amniotic Fluid Volume Adjusted Percentiles and Fetal Weight Adjusted Percentiles?, American Journal of Obstetrics and Gynecology, 190(2), 1610-1615, 2004.
https://doi.org/10.1016/j.ajog.2004.03.069
Shefali, G.; Yadwinder, K.; (2014), Review of Different Local and Global Contrast Enhancement Techniques for a Digital Image, International Journal of Computer Applications, 100(18), 18-23, 2014.
https://doi.org/10.5120/17625-8384
Rajamani, V.; Babu, P.; Jaiganesh, S.; (2013), A Review of various Global Contrast Enhancement Techniques for Still Images using Histogram Modification Framework, International Journal of Engineering Trends and Technology, 44, 1045-1048, 2013.
Kenneth, J. M.; (2013), Toward Consistent Terminology: Assessment and Reporting of Amniotic Fluid Volume, Seminars in Perinatology, Elsevier, 370-374, 2013.
https://doi.org/10.1053/j.semperi.2013.06.016
Onwuzu, S. W. I.; Eze, C. U.; Ugwu, L. C.; Abonyi, O. E.; Adejoh, T.; (2016), Ultrasound Biometry of Normal Human Amniotic Fluid Index in a Nigerian Population, Journal of Radiography, Elsevier, 120(3), 1-7, 2016.
Preethi, G.; Sornagopal, V.; (2014), MRI Image Classification Using GLCM Texture Features, International Conference on Green Computing Communication and Electrical Engineering, Coimbatore, India, 1-6, 2014.
https://doi.org/10.1109/ICGCCEE.2014.6922461
Chen, S.;, Solange, A.; Ron, T.; (1999), Application of a Semiautomatic Boundary Detection Algorithm For The Assessment Of Amniotic Fluid Quantity From Ultrasound Images, Ultrasound in Medical and Biology, Elsevier, 25(4), 515-526, 1999.
https://doi.org/10.1016/S0301-5629(98)00188-4
Sahin, B.; Alper, T,; Kokcu, A.; Malatyalioglu, E.; Kosif, R.; (2003), Estimation of the Amniotic Fluid Volume using the Cavalieri Method on Ultrasound Images, International Journal of Gynecology and Obstetrics, 82(4), 25-30, 2003.
https://doi.org/10.1016/S0020-7292(03)00122-X
Sridevi, S.; Nirmala, S.; (2015), ANFIS based Decision Support System for Prenatal Detection of Truncus Arteriosus Congenital Heart Defect, Journal of Applied Soft Computing, Elsevier, 23(1), 1-11, 2015.
Garima, Y.; Saurabh, M.; Anjali A.; (2014), Contrast Limited Adaptive Histogram Equalization Based Enhancement For Real Time Video System, International Conference on Advances in Computing, Communications and Informatics, New Delhi, India, pp. 2392-2397, 2014.
Additional Files
Published
Issue
Section
License
Copyright (c) 2021 Ramya R, Srinivasan K
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
ONLINE OPEN ACCES: Acces to full text of each article and each issue are allowed for free in respect of Attribution-NonCommercial 4.0 International (CC BY-NC 4.0.
You are free to:
-Share: copy and redistribute the material in any medium or format;
-Adapt: remix, transform, and build upon the material.
The licensor cannot revoke these freedoms as long as you follow the license terms.
DISCLAIMER: The author(s) of each article appearing in International Journal of Computers Communications & Control is/are solely responsible for the content thereof; the publication of an article shall not constitute or be deemed to constitute any representation by the Editors or Agora University Press that the data presented therein are original, correct or sufficient to support the conclusions reached or that the experiment design or methodology is adequate.