Next Article in Journal
Using Data Augmentation to Improve the Generalization Capability of an Object Detector on Remote-Sensed Insect Trap Images
Previous Article in Journal
Reading between the Lines: Process Mining on OPC UA Network Data
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Copper Micro-Flowers for Electrocatalytic Sensing of Nitrate Ions in Water

by
Roberta Farina
1,2,*,
Giuseppe D’Arrigo
1,
Alessandra Alberti
1,
Silvia Scalese
1,
Giuseppe E. Capuano
1,
Domenico Corso
1,
Giuseppe A. Screpis
3,
Maria Anna Coniglio
3,1,
Guglielmo G. Condorelli
2 and
Sebania Libertino
1,*
1
IMM–CNR, Strada VIII Z.I., 5, 95121 Catania, Italy
2
Dipartimento di Scienze Chimiche, Università Degli Studi di Catania, Viale A. Doria 6, 95125 Catania, Italy
3
Dipartimento di Scienze Mediche, Chirurgiche e Tecnologie Avanzate “G.F. Ingrassia”, Università Degli Studi di Catania, Via S. Sofia 87, 95123 Catania, Italy
*
Authors to whom correspondence should be addressed.
Sensors 2024, 24(14), 4501; https://doi.org/10.3390/s24144501
Submission received: 31 May 2024 / Revised: 2 July 2024 / Accepted: 9 July 2024 / Published: 11 July 2024
(This article belongs to the Section Chemical Sensors)

Abstract

:
The progressive increase in nitrate’s (NO3) presence in surface and groundwater enhances environmental and human health risks. The aim of this work is the fabrication and characterization of sensitive, real-time, low-cost, and portable amperometric sensors for low NO3 concentration detection in water. Copper (Cu) micro-flowers were electrodeposited on top of carbon screen-printed electrodes (SPCEs) via cyclic voltammetry (with voltage ranging from −1.0 V to 0.0 V at a scan rate of 0.1 V s−1). The obtained sensors exhibited a high catalytic activity toward the electro-reduction in NO3, with a sensitivity of 44.71 μA/mM. They had a limit of detection of 0.87 µM and a good dynamic linear concentration range from 0.05 to 3 mM. The results were compared to spectrophotometric analysis. In addition, the devices exhibited good stability and a maximum standard deviation (RSD) of 5% after ten measurements; reproducibility, with a maximum RSD of 4%; and repeatability after 10 measurements with the RSD at only 5.63%.

1. Introduction

Nitrogen (N) is an essential macro element for the development of life on earth, as it is present in protein substances, chlorophyll, nucleic acids, etc., and participates in the constitution of most organisms’ tissues. Plants absorb nitrogen from the soil mainly in inorganic forms: nitric and ammoniacal. The ammonium ion binds to the cation exchange complex of the soil; therefore, the ammonium ion is retained and acts more slowly, influenced by microbial activity. The nitrate ion is immediately assimilable, as it is not retained by the soil colloids. This mobility makes it more available for absorption but also more prone to leaching and percolation in the presence of water surpluses. The leached nitrate nitrogen quickly reaches the deeper layers of the soil, becoming unreachable by plant roots and polluting the groundwater and rivers [1]. This causes risks to the environment and human health. The excessive presence of nitrates in drinking water is harmful to our body since they transform into nitrites that bind to hemoglobin to form methemoglobin, which then hinders oxygen transport and flux to tissues in the body [2]. On the other hand, the excess of nitrogen compounds in wastewater causes, with phosphorus, eutrophication, i.e., the uncontrolled proliferation of autotrophic species, especially algae, which become waste for aquatic environments. For these reasons, the World Health Organization (WHO) and European directives set the maximum contaminant level of NO3 in public drinking water to 50 mg/L (~0.8 mM) [3]. To date, several methodologies have been developed to monitor nitrate concentration in water, such as flow injection analysis, spectrophotometry, chemiluminescence, capillary electrophoresis, ion chromatography, high-performance liquid chromatography, and gas chromatography-mass spectrometry [4]. Although these techniques are specific and sensitive, their use presents several drawbacks, such as the need for sampling and the use of sophisticated, expensive, and time-consuming tools. Therefore, substantial research has been oriented toward the development of alternative detection methods that are inexpensive and provide a quick response while still maintaining good sensitivity and selectivity. Electrochemical sensors with screen-printed electrodes (SPEs) are the best candidates. Using screen-printing technology, electrodes with reproducible chemical performances can be developed. Portable systems can be fabricated owing to the small size of SPEs, their linear output, low-power demand, rapid response, high sensitivity, and operating capacity at room temperature [5,6,7]. A screen-printed electrochemical cell is composed of three electrodes: the working electrode (WE), the reference electrode (RE), and the counter electrode (CE), printed on a low-cost solid substrate, often made of ceramic or plastic. The inks used for printing determine the properties of the electrochemical cell, and the appropriate modification of the working electrode surface plays a key role in the development of sensitive and selective electrochemical sensors for molecules/target substance detection [8]. The miniaturized design allows these electrochemical cells to be portable and suitable for on-site measurements and real-time analysis, avoiding the use of large amounts of reagents and samples. All these characteristics agree with green analytical chemistry principles [9,10]. To date, various electrochemical sensors (potentiometric, amperometric, and conductometric [11,12,13,14,15]) have been used to detect NO3. Among copper (Cu), platinum (Pt), silver (Ag), and gold (Au), Cu was proven to be one of the most effective metals for catalyzing the electroreduction in NO3 [16,17]. This is mainly due to its high conductivity (5.8 × 107 S/m), which improves charge transfer [18]. In addition, Cu is the most cost-effective [19] compared to other electrocatalytic metals. Recently, researchers showed that increasing the working electrode electroactive surface area with copper deposition improves the limit of detection (LoD) of electrochemical NO3 sensors [20,21,22]. For instance, a flexible screen-printed amperomeric electrochemical NO3 sensor was developed and functionalized with Cu metal nanoclusters electrodeposited on Ag working electrodes. It showed a high capability to detect NO3 in water with a low calculated LoD 0.207 nM (or 0.012 μg/L) and a dynamic concentration range from 50 to 500 μM (or 31 to 310 mg/L) using linear sweep voltammetry (LSV) [23]. In addition, nitrate detection was investigated using commercial single-walled carbon nanotube-modified Cu and Pd-Cu electrodes in a sulfuric acid solution by LSV. An extended concentration range (0.1 to 7.8 mM) and an LoD of 52 µM were obtained [24]. Therefore, starting from that research, we electrochemically deposited Cu micro-flowers on top of a commercially available carbon electrode using cyclic voltammetry (CV), thus obtaining a low-cost sensor. CV is a powerful electrochemical technique used to study chemical reactions initiated by electron transfer, which includes catalysis [25,26]. Micro-flowers were electrochemically characterized, and their structures were examined using scanning electron microscopy (SEM) and X-ray diffraction (XRD). The sensor showed an LoD of 0.87 µM for NO3 in water and a wide dynamic concentration range, from 0.05 to 3.00 mM (3.1 to 186 mg/L), using LSV. Additionally, sensor stability over time, reproducibility, and repeatability were investigated. Finally, measurements obtained using the developed sensor were compared with those achieved using UV-visible spectrophotometry.

2. Materials and Methods

2.1. Chemicals and Apparatus

Chemicals in this work (all of them are of an analytical grade) were used without further purification. Sodium nitrate (NaNO3), copper sulfate pentahydrate (CuSO4·5H2O), and potassium chloride (KCl) were purchased from Merck KGaA (Darmstadt, Germany). milliQ water (resistivity of at least 18.2 MΩ cm) obtained by Simplicity UV (Millipore, by Merk, Darmstadt, Germany) was used for the preparation of all solutions. Screen-printed carbon electrodes (SPCE, cod. Ref. 150) were bought from Metrohm DropSens s.r.l. (Origgio, VA, Italy). Copper electrodeposition and all electrochemical measurements were performed by the Palmsens4 electrochemical workstation by PalmSens BV (C-PS4-BP.F2.10, GA Houten, The Netherlands). An UV-vis spectrophotometer (Varian Cary 50, Palo Alto, CA, USA) was used to compare the electrochemical data with a standard measurement. Scanning electron microscopy (SEM) was conducted using an e-beam lithography apparatus Raith 150 (Dortmund, Germany) in the SEM operation mode. EDX spectra were obtained by an energy-dispersive X-ray microanalysis system (X-MAX, 80 mm2 by Oxford Instruments, Abingdon, UK) inside a ZEISS FE-SEM SUPRA 35 (Carl Zeiss AG, Jena, Germany). X-ray diffraction patterns were collected using Smartlab equipment made by Rigaku (Sevenoaks, UK).
Electrochemical measurements were performed in milliQ water solutions containing KCl 0.1 M. Spectrophotometric measurements were performed by measuring the nitrate peak height at 205 nm in the same electrochemical solutions.

2.2. Copper Micro-Flowers Electrodeposition and Storage

Copper was CV electrochemically deposited on an SPCE (4 mm diameter) surface by performing 5 cycles in the potential range from 1.0 to 0.0 V at a scan rate of 0.1 V s−1, and 0.1 M CuSO4 in 0.1 M KCl, supporting the electrolyte solution [27]. The electrochemical cell of SPCE is a three-electrode composed of single-sided carbon WE, silver RE, and platinum CE. The solution was not stirred during deposition. Each cycle lasted roughly 2 min. This electrochemical process created Cu micro-flowers on the carbon surface [28]. Once fabricated, the electrodes were either used immediately or stored under a nitrogen atmosphere to avoid Cu oxidation. After each measurement, the electrodes were rinsed in milliQ water, dried under N2 flux, and stored in an N2 atmosphere.

2.3. Electrochemical Characterization

Figure 1a shows the CV of a bare carbon electrode (red trace) and modified Cu/C electrode (blue trace) performed in a 0.1 M KCl electrolyte solution. E0 is the characteristic peak of the SPCE, which flattens in the case of the modified electrode, proving the coverage. Compared to the bare C electrode, the modified electrode shows two cathodic peaks at −0.33 V (E1) and −0.75 V (E2), characteristic of Cu(I) and Cu(II), respectively. Their presence confirms the success of the copper electrodeposition process.
Figure 1b shows the CV of a bare carbon electrode (red trace) and of a modified Cu/C electrode (blue trace) performed in the presence of nitrate (1.6 mM NO3) in an electrolyte solution (0.1 M KCl). The bare C electrode CV remained unchanged, while two additional reduction peaks at −0.86 V (E3) and −1.08 V (E4) appeared in the Cu/C electrode CV. These peaks can be ascribed to the reduction in NO3 (peak E3) and NO2 (peak E4) ions.
Calibration curve measurements and reproducibility tests were performed on solutions containing NO3 to 0.05, 0.15, 0.5, 0.8, 1.5, 1.8, and 3.0 mM. The same solutions were used for electrochemical and spectrophotometric measurements. After each measurement, lasting roughly 10 s, the electrode was rinsed in milliQ water and dipped in the solution for the next measurement. Time stability was measured using a 2 mM NO3 solution and performing ten measurements in a three-day timeframe.

3. Results

3.1. Morphological Characterization

Scanning electron micrographs were acquired to study the C surface and the electrodeposited copper morphologies. Figure 2a shows the uniform distribution of Cu micro grains all over the SPCE electrode surface. The carbon surface is still visible, suggesting that electrode porosity is preserved. Figure 2b shows the magnification of the Cu grain structures obtained after five Cu electrodeposition cycles on the WE. Flower-shaped crystals with a specific orientation were deposited. Cu micro-flowers have a high surface-to-volume ratio from 0.01 to 1 along a well-defined orientation (see after) with a profile width ranging from 0.5 to 4.5 μm (Figure S1).
The flower-like structure of the crystallites favors a greater catalytic effect. Their formation is associated with the anion-induced directional growth of Cu crystal planes [29]; this effect fully exposes the active sites and increases the synergetic catalytic efficiency [30,31]. To evaluate and quantify the elemental composition of the bare carbon WE and the modified Cu/C WE, energy-dispersive X-ray spectroscopy (EDS) analysis was performed. The estimated composition of the WE surface revealed % weight values of 90.40% of C, 2.54% of O, 0.36% of Si, 6.86% of Cl (Figure S2) for the bare carbon WE, and % weight values of 70.05% Cu, 21.10% Cl, 6.98% C, and 1.88% O (Figure S3) for the modified Cu/C electrode. Notably, the percentage values obtained for each element provided an average surface value of the sample since the Cu structures did not form a fully homogeneous and flat coverage on the bare carbon WE. Hence, the obtained values were in the expected range and revealed that most of the electrode surface is covered with electrodeposited Cu.
Cu deposited on the surface of the WE was characterized by X-ray diffraction (XRD) to evaluate its crystallographic structure. The XRD pattern of the bare electrode and modified electrode with five CV cycles of copper deposition are shown in Figure 3.
The modified electrode shows peaks at positions (2θ) of 50.48° and 74.13° corresponding to the Bragg reflections of crystalline Cu(200) and Cu(220), and peaks at positions (2θ) of 36.18°, 39.76°, 47.46° corresponding to CuO(002), CuO(022), and CuO(−202), respectively. The modified electrode shows peaks at positions (2θ) of 46.3°, corresponding to CuCl(220). This pattern confirms the successful coverage with crystalline Cu on top of the C WE. Additionally, the observation is analogous to that of Inam et al. [23] and Chen et al. [32], who demonstrated that the morphology of Cu electro-crystallization is driven by the surface energy differences in the crystallographic planes. The high-index facet exhibits a high density of low-coordinated atoms, providing more catalytic sites for electrocatalysts [33].
Various Cu crystallographic orientations exhibit distinct surface energies, impacting thermodynamic stability, nitrate molecule adsorption capacity, and reactivity. Additionally, different crystallographic orientations present varying densities of active sites, affecting the number of sites available for catalytic reactions. Metallic copper is known to enhance nitrate reduction due to its high electrical conductivity and abundant conduction electrons. In contrast, the presence of chlorine can adversely affect the nature of the active sites on the surface and their interactions with nitrates.
Therefore, XRD measurements provide information, besides Cu, on all the compounds present in the sample. Their formation is associated with the anion-induced directional growth of copper crystal planes; this effect fully exposes the active sites and increases the synergetic catalytic efficiency. The atomic arrangement of different crystal planes can influence the adsorption of reaction intermediates, thereby impacting the activity and selectivity of electrocatalysts for NO3 [33,34,35,36,37,38].

3.2. Study of the Electrochemical Reaction on Electrodes

The nature of the electrochemical reaction taking place on the Cu/C electrode was studied. The energy levels of their highly occupied d-orbitals were closely aligned with the lowest unoccupied molecular π* orbital of NO3⁻, facilitating efficient electron transfer at the catalyst surface. Therefore, the effect of the scanning speed, from 50 to 500 mVs−1, on the NO3 reduction peak current was examined [33].
Figure 4a shows that the potential (Ep) at which the NO3 reduction occurs shifts negatively when the scan rate increases. This characteristic behavior is associated with a diffusion-controlled irreversible electron transfer process [31]. Figure 4b summarizes the cathodic peak current as a function of the square root of the scan rate. It shows the cathodic peak current increased linearly with the scan rate, indicating a diffusion-controlled reduction process, as described by the Randles–Ševčík equation [39] (Equation (1)):
i p = 2.69 × 10 5   n 3 2   A D 0 1 2   v 1 2   C
where ip is the peak current, n is the number of electron transfers (2 for NO3), A is the active surface area (cm2), Do is the diffusion coefficient (2.0 × 10−6 cm2 s−1 for NO3), v is the scan rate (V s−1), and C is the NO3 concentration (mol cm−3). The Randles–Sevcik equation is a tool in electrochemistry that allows us to relate three key parameters: surface area, diffusion coefficient, and redox concentration. By employing this equation, the effective electrochemical surface areas of both C and Cu/C WE were calculated, obtaining values of 0.0197 cm2 and 0.0404 cm2, respectively, showing that the Cu electrodeposition induces an increase in the effective surface of more than 100%. To study the kinetics of the reaction on an electrode, the half-peak potential (Ep/2), defined as the potential corresponding to ip/2, is usually examined [40]. Figure S5 shows the ΔEp/2 = Ep − Ep/2 calculated and plotted as a function of the scan rate. These data indicate that the transfer coefficient of the reduction reaction is independent of the scan rate.

3.3. Electrochemical Sensor Performance for Nitrate Ion Detection

To study the electrochemical sensor analytical performances, linear sweep voltammetry was used to detect NO3 in a 0.1 M KCl electrolyte solution (pH = 7). The KCl electrolyte solution is an excellent medium since it allows the NO3 content to be directly measured in water without changing the electrolytes’ pH or interfering with the sensor’s performance. The average of three measurements of the NO3 reduction peak current at 0.86 V over the 0.05–3.0 mM concentration range was used to construct a calibration plot. The data show a linear detection range from 0.05 to 3 mM with a sensitivity of 44.71 μA/mM and a coefficient of determination (R2) of 99.28% (N = 3) (Figure S6). Based on a signal-to-noise ratio of three, the limit of detection (LoD) was estimated to be 0.87 µM. It can be seen that the Cu(II) reduction peak amplitude increased linearly with the nitrate concentration. This observation can be explained by the catalytic effect of the copper. Filimonov et al. [41] demonstrated that cuprous ions exhibit a catalytic effect with nitrate since they are electrochemically active and, as a result, an increase in the mass transport and the electron transfer process can be obtained.
Measurements performed using the reported sensor were compared with absorbance measurements by UV-vis spectrophotometry. The measurements obtained by the two instruments are summarized in Figure 5. The calibration plot for red circles refers to the right axis as the spectrophotometer dataset, and the blue squares refer to the left vertical axis and represent the average of three peak currents. The data show that the electrochemical sensor has a sensitivity only 1.61 times lower than that of the spectrophotometer one, demonstrating the good quality of the developed sensor [42].

3.4. Reproducibility, Repeatability, and Stability of the Sensor

Reproducibility, repeatability, and sensor stability were evaluated. Reproducibility was studied by carrying out measurements on the same solution with three different electrodes manufactured using the same procedure; instead, repeatability was studied by carrying out repeated measurements with the same electrode on the same solution. Electrodes were rinsed with milliQ water and dried with compressed air before performing each test. For the reproducibility test, the electrodes were tested at seven different concentrations of NO3 (0.05, 0.15, 0.5, 0.8, 1.5, 1.8, and 3.0 mM); the measurements at each concentration were carried out three times. The relative standard deviations (RSDs) were 0.15%, 0.39%, 0%, 4.89%, 0.02%, 2.83%, and 0%, respectively, demonstrating good reproducibility, as shown in Figure 6a (The table containing all the data is reported in the Supplementary Material, Table S1). This result was achieved owing to the good quality of the functionalization process, which ensures excellent homogeneity and reproducibility of the deposition of the sensitive material.
The repeatability test was carried out using the same electrode (10 consecutive measurements) in the same NO3 (0.8 mM) solution. The RSD was calculated by comparing the amplitude of the reduction peak current of the subsequent measurements with the first one. The concentration of 0.8 mM was selected as a reference since it was set as the maximum limit accepted by the WHO and European directives. The calculated RSDs were 0%, 0.8%, 1.37%, 2.61%, 3.18%, 3.74%, 4.15%, 4.63%, 5.10%, and 5.63%, respectively, for the seven NO3 concentrations, demonstrating good repeatability, as shown in Figure 6b. In addition, the sensor had a stable behavior up to the tenth measurement, characterized by a reduction of 5% in the amplitude of the NO3 cathodic peak compared to the first measurement. This ensured that the sensor could be reused but only for a limited number of measurements. This result is promising because the sensor developed in this work shows greater reproducibility than the works reported in the literature to our knowledge [23]. Stability over time was measured using a 2 mM NO3 solution, indicating that the sensor, properly stored, is stable after three days of measurements.
Finally, the sensor can also be used in impure water. We tested the device using tap water as the solution medium. The data (shown in Figure S7 of the Supplementary Material) demonstrate that the medium purity does not affect the calibration curve, thus implying that none of the impurities contained in tap water affect the device’s performance.

4. Conclusions

In this work, a carbon screen-printed electrochemical sensor for NO3 detection in water was fabricated by the electrodeposition of Cu and characterized both in terms of fabrication parameters and performances in detection. The device, obtained after five electrodeposition cycles, CV, partially covered the C surface with Cu micro-flowers, the presence of which increased the electrode active surface area by more than 100% compared to the bare carbon electrode. NO3 has been quantitatively determined in the range extending from 0.05 to 3.00 mM with an estimated limit of detection of 0.87 µM in neutral media composed of a 0.1 M electrolyte solution of KCl. The sensor showed high reproducibility with a maximum RSD of 4%. The repeatability test confirmed that the same sensor shows an RSD of 5.63% after the tenth measurement on the same solution. In addition, the sensor is stable up to the tenth measurement, which is characterized by a reduction of 5% in the amplitude NO3 cathodic peak compared to the first one. Measurements made with the proposed portable sensor were compared with absorbance measurements by UV-vis spectrophotometry, showing a sensitivity of only a factor 1.6 lower than the benchtop instrument. The proposed sensor also works with tap water; hence, it can be easily implemented in precision agriculture as a low-cost, fast, specific, and sensitive sensor for the detection of nitrate ions in irrigation water.

5. Patents

R. Farina and S. Libertino, Nitrates electrocatalytic detection in water by copper micro-flowers, under the patenting procedure, filed the 11 March 2024, n. 102024000005344, at the Italian “Ministero delle Imprese e del Made in Italy”.

Supplementary Materials

The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/s24144501/s1. Figure S1: Scanning electron micrographs of magnification images of screen-printed C WE modified through 5 cycles of Cu electrodeposition. Profile width estimation; Figure S2: EDS of screen-printed bare C WE; Figure S3: EDS of screen-printed C WE modified through 5 cycles of Cu electrodeposition; Figure S4: Reproducibility test for Cu/C sensor. NO3 peak current as a function of NO3 concentration (mM); Figure S5: ΔEp/2 as a function of the scan rate for nitrate reduction; Figure S6: Reproducibility test for Cu/C sensor. NO3 peak current as a function of NO3 concentration (mM); Figure S7: Calibration curves for NO3 concentration added to milliQ water (blue dots) and to tap water (green squares) and Table S1: Measurements of peak current and relative standard deviation as a function of the nitrate concentration.

Author Contributions

Conceptualization, R.F. and S.L.; methodology, R.F., D.C., G.E.C., G.A.S., A.A. and G.D.; formal analysis, R.F., G.E.C., G.A.S., D.C., A.A. and G.D.; investigation, R.F., G.D., A.A. and S.S.; resources, S.L.; data curation, R.F., G.D., A.A., G.E.C., G.A.S. and D.C.; writing—original draft preparation, R.F.; writing—review and editing, R.F., G.A.S., A.A., S.S., D.C., G.E.C., G.A.S., G.G.C., M.A.C. and S.L.; supervision, G.G.C. and S.L.; project administration, S.L. and M.A.C.; funding acquisition, S.L. All authors have read and agreed to the published version of the manuscript.

Funding

The research activities were partially funded by the European Union (NextGeneration EU), through the MUR-PNRR project SAMOTHRACE [GA ECS00000022]; the European project TELEGRAM of the European Union’s Horizon 2020 Research and Innovation Programme [GA 101006941]. Part of this work has been carried out as part of the Italian Infrastructure Beyond-Nano co-funded by Regione Sicilia (D.D.G. 2929/5S) and by the Italian Ministry of University and Research (Decree 2510/2019).

Data Availability Statement

The raw data supporting the conclusions of this article are included in the paper and Supplementary Material figures and tables.

Conflicts of Interest

The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

References

  1. Forde, B.G.; Clarkson, D.T. Nitrate and Ammonium Nutrition of Plants: Physiological and Molecular Perspectives. In Advances in Botanical Research; Callow, J.A., Ed.; Elsevier: Amsterdam, The Netherlands, 1999; Volume 30, pp. 1–90. [Google Scholar] [CrossRef]
  2. Bryan, N.S.; van Grinsven, H. Chapter Three—The Role of Nitrate in Human Health. In Advances in Agronomy; Sparks, D.L., Ed.; Elsevier: Amsterdam, The Netherlands, 2013; Volume 119, pp. 153–182. [Google Scholar] [CrossRef]
  3. World Health Organization. Water, Sanitation and Health Team. Guidelines for Drinking-Water Quality: Incorporating First Addendum, Recommendations; World Health Organization: Geneva, Switzerland, 2006; Volume 1. [Google Scholar]
  4. Zhang, J.-Z.; Fischer, C.J. A simplified resor-cinol method for direct spectrophotometric de-termination of nitrate in seawater. Mar. Chem. 2006, 99, 220–226. [Google Scholar] [CrossRef]
  5. Tse, Y.-H.; Janda, P.; Lam, H.; Lever, A.B.P. Electrode with electropolymerized tetraaminophthalocyanatocobalt(II) for detection of sulfide ion. Anal. Chem. 1995, 67, 981–985. [Google Scholar] [CrossRef]
  6. Hori, Y.; Takahashi, R.; Yoshinami, Y.; Murata, A. Electrochemical Reduction of CO at a Copper Electrode. J. Phys. Chem. B 1997, 101, 7075–7081. [Google Scholar] [CrossRef]
  7. Ferrari, A.G.-M.; Rowley-Neale, S.J.; Banks, C.E. Screen-printed electrodes: Transitioning the laboratory in-to-the field. Talanta Open 2021, 3, 100032. [Google Scholar] [CrossRef]
  8. Hanrahan, G.; Patil, D.G.; Wang, J. Electrochemical sensors for environmental monitoring: Design, development and applications. J. Environ. Monit. 2004, 6, 657–664. [Google Scholar] [CrossRef] [PubMed]
  9. Yáñez-Sedeño, P.; Campuzano, S.; Pingarrón, J.M. Electrochemical (bio)sensors: Promising tools for green analytical chemistry. Curr. Opin. Green Sustain. Chem. 2019, 19, 1–7. [Google Scholar] [CrossRef]
  10. Gałuszka, A.; Migaszewski, Z.; Namieśnik, J. The 12 principles of green analytical chemistry and the SIGNIFICANCE mnemonic of green ana-lytical practices. TrAC Trends Anal. Chem. 2013, 50, 78–84. [Google Scholar] [CrossRef]
  11. Bagheri, H.; Hajian, A.; Rezaei, M.; Shir-zadmehr, A. Composite of Cu metal nanoparticles multiwall carbon nanotubes-reduced graphene oxide as a novel and high performance platform of the electrochemical sensor for simultaneous determination of nitrite and nitrate. J. Hazard. Mater. 2017, 324, 762–772. [Google Scholar] [CrossRef]
  12. Li, Y.; Li, H.; Song, Y.; Lu, H.; Tong, J.; Bian, C.; Sun, J.; Xia, S. An Electrochemical Sensor System with Renewable Copper Nano-Clusters Modified Electrode for Continuous Nitrate Determination. IEEE Sens. J. 2016, 16, 8807–8814. [Google Scholar] [CrossRef]
  13. Ryu, H.; Thompson, D.; Huang, Y.; Li, B.; Lei, Y. Electrochemical sensors for nitrogen species: A review. Sens. Actuators Rep. 2020, 2, 100022. [Google Scholar] [CrossRef]
  14. Ronkainen, N.J.; Halsall, H.B.; Heineman, W.R. Electrochemical biosensors. Chem. Soc. Rev. 2010, 39, 1747–1763. [Google Scholar] [CrossRef] [PubMed]
  15. Hassan, M.H.; Khan, R.; Andreescu, S. Advances in electrochemical detection methods for measuring contaminants of emerging concerns. Electrochem. Sci. Adv. 2022, 2, e2100184. [Google Scholar] [CrossRef]
  16. Dima, G.E.; De Vooys, A.C.A.; Koper, M.T.M. Electrocatalytic reduction of nitrate at low concentration on coinage and transition-metal electrodes in acid solutions. J. Electroanal. Chem. 2003, 554–555, 15–23. [Google Scholar] [CrossRef]
  17. Wang, J.; Zhang, Z.; Wang, S. Facile fabrication of Ag/GO/Ti electrode by one-step electro-deposition for the enhanced cathodic reduction of nitrate pollution. J. Water Process. Eng. 2021, 40, 101839. [Google Scholar] [CrossRef]
  18. Li, Y.; Bian, C.; Xia, S.; Sun, J.; Tong, J. Micro electrochemical sensor with copper nanoclusters for nitrate determination in freshwaters. Micro Nano Lett. 2012, 7, 1197–1201. [Google Scholar] [CrossRef]
  19. Frag, E.Y.; Mohamed, M.E.-B.; Salem, H.S. Preparation and characterization of in situ car-bon paste and screen-printed potentiometric sensors for determination of econazole nitrate: Surface analysis using SEM and EDX. J. Iran. Chem. Soc. 2017, 14, 2355–2365. [Google Scholar] [CrossRef]
  20. Motaghedifard, M.H.; Pourmortazavi, S.M.; Alibolandi, M.; Mirsadeghi, S. Au-modified organ-ic/inorganic MWCNT/Cu/PANI hybrid nano-composite electrode for electrochemical determination of nitrate ions. Microchim. Acta 2021, 188, 99. [Google Scholar] [CrossRef] [PubMed]
  21. Ambaye, A.D.; Muchindu, M.; Jijana, A.; Mishra, S.; Nxumalo, E. Screen-printed electrode system based on carbon black/copper-organic frame-work hybrid nanocomposites for the electro-chemical detection of nitrite. Mater. Today Commun. 2023, 35, 105567. [Google Scholar] [CrossRef]
  22. Wang, X.; Zhu, M.; Zeng, G.; Liu, X.; Fang, C.; Li, C. A three-dimensional Cu nanobelt cathode for highly efficient electrocatalytic nitrate reduction. Nanoscale 2020, 12, 9385–9391. [Google Scholar] [CrossRef]
  23. Inam, A.K.M.S.; Angeli, M.A.C.; Shkodra, B.; Douaki, A.; Avancini, E.; Magagnin, L.; Petti, L.; Lugli, P. Flexible Screen-Printed Electrochemical Sensors Functionalized with Electrodeposited Copper for Nitrate Detection in Water. ACS Omega 2021, 6, 33523–33532. [Google Scholar] [CrossRef]
  24. Hyusein, C.; Tsakova, V. Nitrate detection at Pd-Cu-modified carbon screen printed electrodes. J. Electroanal. Chem. 2023, 930, 117172. [Google Scholar] [CrossRef]
  25. Elgrishi, N.; Rountree, K.J.; McCarthy, B.D.; Rountree, E.S.; Eisenhart, T.T.; Dempsey, J.L. A Practical Beginner’s Guide to Cyclic Voltammetry. J. Chem. Educ. 2018, 95, 197–206. [Google Scholar] [CrossRef]
  26. Bard, A.J.; Faulkner, L.R. Electrochemical Methods: Fundamentals and Applications, New York: Wiley, 2001, 2nd ed. Russ. J. Electrochem. 2002, 38, 1364–1365. [Google Scholar] [CrossRef]
  27. Mumtarin, Z.; Rahman, M.M.; Marwani, H.M.; Hasnat, M.A. Electro-kinetics of conversion of NO3 into NO2 and sensing of nitrate ions via re-duction reactions at copper immobilized plati-num surface in the neutral medium. Electrochim. Acta 2020, 346, 135994. [Google Scholar] [CrossRef]
  28. Grujicic, D.; Pesic, B. Electrodeposition of copper: The nucleation mechanisms. Electrochim. Acta 2022, 47, 2901–2912. [Google Scholar] [CrossRef]
  29. Ngamchuea, K. An overview of the voltammetric behaviour of Cu single-crystal electrodes. Curr. Opin. Electrochem. 2023, 37, 101193. [Google Scholar] [CrossRef]
  30. Lotfi Zadeh Zhad, H.R.; Lai, R.Y. Comparison of nanostructured silver-modified silver and carbon ultramicroelectrodes for electro-chemical detection of nitrate. Anal. Chim. Acta 2015, 892, 153–159. [Google Scholar] [CrossRef] [PubMed]
  31. Zhao, Y.; Liu, Y.; Zhang, Z.; Mo, Z.; Wang, C.; Gao, S. Flower-like open-structured polycrystalline copper with synergistic multi-crystal plane for efficient electrocatalytic reduction of nitrate to ammonia. Nano Energy 2022, 97, 107124. [Google Scholar] [CrossRef]
  32. Chen, D.-J.; Lu, Y.-H.; Wang, A.-J.; Feng, J.-J.; Huo, T.-T.; Dong, W.-J. Facile synthesis of ultra-long Cu microdendrites for the electrochemical detection of glucose. J. Solid State Electrochem. 2012, 16, 1313–1321. [Google Scholar] [CrossRef]
  33. Zhang, R.; Zhang, S.; Cui, H.; Guo, Y.; Li, N.; Zhi, C. Electrochemical nitrate reduction to ammonia using copper-based electrocatalysts. Next Energy 2024, 4, 100125. [Google Scholar] [CrossRef]
  34. Patil, S.B.; Liu, T.-R.; Chou, H.-L.; Huang, Y.-B.; Chang, C.-C.; Chen, Y.-C.; Lin, Y.-S.; Li, H.; Lee, Y.-C.; Chang, Y.J.; et al. Electrocatalytic Reduction of NO3 to Ultrapure Ammonia on {200} Facet Dominant Cu Nanodendrites with High Conversion Faradaic Efficiency. J. Phys. Chem. Lett. 2021, 12, 8121–8128. [Google Scholar] [CrossRef] [PubMed]
  35. Shih, Y.J.; Wu, Z.L.; Huang, Y.H.; Huang, C.P. Electrochemical nitrate reduction as affected by the crystal morphology and facet of copper nanoparticles supported on nickel foam electrodes (Cu/Ni). Chem. Eng. J. 2020, 383, 123157. [Google Scholar] [CrossRef]
  36. Qin, J.; Chen, L.; Wu, K.; Wang, X.; Zhao, Q.; Li, L.; Liu, B.; Ye, Z. Electrochemical Synthesis of Ammonium from Nitrates via Surface Engineering in Cu2O(100) Facets. ACS Appl. Energy Mater. 2022, 5, 71–76. [Google Scholar] [CrossRef]
  37. Wang, Y.; Qin, X.; Shao, M. First-principles mechanistic study on nitrate reduction reactions on copper surfaces: Effects of crystal facets and pH. J. Catal. 2021, 400, 62–67. [Google Scholar] [CrossRef]
  38. Chen, L.-F.; Xie, A.-Y.; Lou, Y.-Y.; Tian, N.; Zhou, Z.-Y.; Sun, S.-G. Electrochemical synthesis of Tetrahexahedral Cu nanocrystals with high-index facets for efficient nitrate electroreduction. J. Electroanal. Chem. 2022, 907, 116022. [Google Scholar] [CrossRef]
  39. González-Meza, O.A.; Larios-Durán, E.R.; Gutiérrez-Becerra, A.; Casillas, N.; Escalante, J.I. Development of a Randles-Ševčík-like equation to predict the peak current of cyclic voltammetry for solid metal hexacyanoferrates. J. Solid State Electrochem. 2019, 23, 3123–3133. [Google Scholar] [CrossRef]
  40. Bontempelli, G.; Dossi, N.; Toniolo, R. Chemistry, Molecular Sciences and Chemical Engineering/Linear Sweep and Cyclic; Elsevier Inc.: Amsterdam, The Netherlands, 2016; pp. 1–10. [Google Scholar]
  41. Filimonov, E.V.; Shcherbakov, A.I. Catalytic Effect of Copper Ions on Nitrate Reduction. Prot. Met. 2004, 40, 280–285. [Google Scholar] [CrossRef]
  42. Farina, R.; Libertino, S. Nitrates Electrocatalytic Detection in Water by Copper Microflowers. Italian Patent 102024000005344, Requested on 11 March 2024.
Figure 1. (a) Cyclic voltammograms in 0.1 M KCl supporting the electrolyte of (a) the bare C electrode (red trace) and electrodeposited Cu/C electrode (blue trace); (b) the bare C electrode (red trace) and an electrodeposited Cu/C electrode (blue trace) in the presence of 1.6 mM NO3.
Figure 1. (a) Cyclic voltammograms in 0.1 M KCl supporting the electrolyte of (a) the bare C electrode (red trace) and electrodeposited Cu/C electrode (blue trace); (b) the bare C electrode (red trace) and an electrodeposited Cu/C electrode (blue trace) in the presence of 1.6 mM NO3.
Sensors 24 04501 g001
Figure 2. SEM images of screen-printed C WE modified with 5 electro-deposition cycles of Cu. (a) Large area image (marker 2 µm); (b) magnification of a single Cu flower (marker 200 nm).
Figure 2. SEM images of screen-printed C WE modified with 5 electro-deposition cycles of Cu. (a) Large area image (marker 2 µm); (b) magnification of a single Cu flower (marker 200 nm).
Sensors 24 04501 g002
Figure 3. XRD pattern of bare and modified electrodes with 5 CV cycles of copper deposition.
Figure 3. XRD pattern of bare and modified electrodes with 5 CV cycles of copper deposition.
Sensors 24 04501 g003
Figure 4. (a) The NO3 reduction peak potential as a function of the scan rate. (b) Maximum peak current as a function of the square root of the scan rate. The dashed red line is the linear best fit of the data.
Figure 4. (a) The NO3 reduction peak potential as a function of the scan rate. (b) Maximum peak current as a function of the square root of the scan rate. The dashed red line is the linear best fit of the data.
Sensors 24 04501 g004
Figure 5. Calibration curve for nitrate detection for UV-vis spectrophotometer (red circles refer to the right axis) and the Cu/C sensor (blue squares refer to the left vertical axis). Each point represents the average peak current performed by three measurements.
Figure 5. Calibration curve for nitrate detection for UV-vis spectrophotometer (red circles refer to the right axis) and the Cu/C sensor (blue squares refer to the left vertical axis). Each point represents the average peak current performed by three measurements.
Sensors 24 04501 g005
Figure 6. (a) Reproducibility test for Cu/C sensor. NO3 peak current as a function of NO3 concentration (mM); (b) Repeatability test for Cu/C sensor. The reduction peak current of the NO3 was acquired from the same sample by repeating the measurement 10 times. The percentage reported in the Figure is the difference between the successive measurements from the first one.
Figure 6. (a) Reproducibility test for Cu/C sensor. NO3 peak current as a function of NO3 concentration (mM); (b) Repeatability test for Cu/C sensor. The reduction peak current of the NO3 was acquired from the same sample by repeating the measurement 10 times. The percentage reported in the Figure is the difference between the successive measurements from the first one.
Sensors 24 04501 g006
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Farina, R.; D’Arrigo, G.; Alberti, A.; Scalese, S.; Capuano, G.E.; Corso, D.; Screpis, G.A.; Coniglio, M.A.; Condorelli, G.G.; Libertino, S. Copper Micro-Flowers for Electrocatalytic Sensing of Nitrate Ions in Water. Sensors 2024, 24, 4501. https://doi.org/10.3390/s24144501

AMA Style

Farina R, D’Arrigo G, Alberti A, Scalese S, Capuano GE, Corso D, Screpis GA, Coniglio MA, Condorelli GG, Libertino S. Copper Micro-Flowers for Electrocatalytic Sensing of Nitrate Ions in Water. Sensors. 2024; 24(14):4501. https://doi.org/10.3390/s24144501

Chicago/Turabian Style

Farina, Roberta, Giuseppe D’Arrigo, Alessandra Alberti, Silvia Scalese, Giuseppe E. Capuano, Domenico Corso, Giuseppe A. Screpis, Maria Anna Coniglio, Guglielmo G. Condorelli, and Sebania Libertino. 2024. "Copper Micro-Flowers for Electrocatalytic Sensing of Nitrate Ions in Water" Sensors 24, no. 14: 4501. https://doi.org/10.3390/s24144501

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop