Device for Connection of Luminaires

Device for Connection of Luminaires (DCL) is a European standard for ceiling light fixtures introduced in 2005 and refined in 2009. It uses 6 ampere. DCL must carry the CE marking as per the Low Voltage Directive. DCL is only allowed to be installed with ground.

DCL
Type Ceiling lamp connector
Production history
Designer IEC
Designed 2005; 19 years ago (2005)
Manufacturer Elko, Legrand, Schneider Electric, Lébénoïd, more
General specifications
Length 24.2 mm + length of pins
Width 30.2 mm
Audio signal None
Video signal None
Cable Electrical
Pins 3
Connector DCL
Electrical
Signal 6 ampere
Earth Yes
Max. voltage 250 V AC
Max. current 6 A
Data
Data signal None
Pinout
Pin 1 Load L
Pin 2 Protective earth PE
Pin 3 Neutral N
3 on the plug, 6 inside the socket.
Example of DCL socket.
Plug (external)
Pin Color Function
1 Load (L)
2 Protective earth
3 Neutral (N)
Socket internals
Pin Color Function
1 Load (L)
2 Load (L)
3 Protective earth
4 Protective earth
5 Neutral (N)
6 Neutral (N)

Adoption

edit
Country Notes
  Austria
  Belgium
  Bulgaria
  Croatia
  Cyprus
  Czech Republic
  Denmark
  Estonia
  Finland
  France Mandatory in new and renovated homes since 2001. Norme Française NF C 15-100.
  Germany
  Greece
  Hungary
  Republic of Ireland
  Italy
  Latvia
  Lithuania
  Luxembourg
  Malta
  Netherlands
  Poland
  Portugal
  Romania
  Slovakia
  Slovenia
  Spain
  Sweden Mandatory since April 1, 2019
Non-EU countries
Country Notes
  Norway Mandatory since December 31, 2010
edit