26<br />
Troubleshooting<br />
Error code Fault description<br />
Display<br />
Time exceeded – blowing cold<br />
Safety time exceeded<br />
Flame aborted from control stage<br />
“large”<br />
Flame aborted from control stage<br />
“small”<br />
Temperature sensor – interruption<br />
Please note<br />
The test with a bridge in the 14-pole<br />
connector can only be performed if<br />
HYDRONIC is still installed in the<br />
vehicle or if a test facility is available.<br />
Temperature sensor – short-circuit,<br />
overload or accidental ground<br />
Please note<br />
The test with a bridge in the 14-pole<br />
connector can only be performed if<br />
HYDRONIC is still installed in the<br />
vehicle or if a test facility is available.<br />
Explanations<br />
Remedies<br />
At start, flame sensor reports temperature > 70°C for longer<br />
than 240°C.<br />
Check exhaust and combustion air guidance.<br />
Check flame sensor – control values see page 34.<br />
Check exhaust and combustion air guidance.<br />
Check fuel quantity and fuel supply, see page 41.<br />
Clean or replace filter in dosing pump connection.<br />
Warning<br />
After flame aborted from control stage “large” or “small” and<br />
after starting attempt within allowed number, HYDRONIC<br />
proceeds with a new start, where applicable with subsequent<br />
start repeat.<br />
If the new start or start repeat is successful, the error code is<br />
deleted.<br />
Error (because no more starting attempts allowed)<br />
Check exhaust and combustion air guidance.<br />
Check fuel quantity and fuel supply, see page 41.<br />
Check flame sensor, see error code 064 and 065.<br />
Remove controller and check connection lead of temperature<br />
sensor for any signs of damage. If the lead is OK, then<br />
short the temperature sensor: route the cable in the 14-pole<br />
connector from chamber 3 to chamber 4.<br />
Switch HYDRONIC on:<br />
– If error code 061 appears, then remove and check<br />
temperature sensor, see page 38.<br />
– If error code 060 still appears, then check and if<br />
necessary replace controller.<br />
Remove controller and check connection lead of<br />
temperature sensor for any signs of damage. If the lead is<br />
OK, then remove the 14-pole connector from controller,<br />
unclip cable 0.5 2 blue from chamber 3 and cable 0.5 2 blue<br />
from chamber 4.<br />
Connect 14-pole connector to controller and switch<br />
HYDRONIC on.<br />
– If error code 061 appears, then remove and check<br />
temperature sensor, see page 38.<br />
– If error code 061 appears, then check and if necessary<br />
replace controller.